Cylinder Sensor Ifm MK5907


IFM CATEGORIES

Cylinder Sensor Ifm mk5907

Cylinder Sensor MK5907

Brand: Ifm
Product Code: MKT4028BFRKG/H/0,3M/IO/ZH/ASR

  • Single sensor for two end positions for short-stroke cylinders
  • End position adjustment assistance with additional LED indicator
  • Inline quality inspection with a 50 mm detection range

Share on:

Product characteristics

Electrical engineering design PNP/NPN; (customizable)
Output feature typically open / closed; (customizable)
communication interface IO-Link
Operating principle Hall sensor; (3D function)
Configuration options Switching points; Count function; Diagnostic capability
Weight[g] 14.95
Installation recessed installation compatible
Method of installation fastening component with integrated head slot / hex socket AF 1.5
Cylinder design T-slot actuators
Substance enclosure: PA; retention clamp: stainless steel

Interfaces

communication interface IO-Link
Mode of transmission COM2 (38,4 kBaud)
IO-Link version 1.1.3
SDCI specification IEC 61131-9 CDV
Configurations
Operation classOverview
0x0010Measuring and switching sensor, single channel / SSP 4.1.1
0x4000Identification and Fault Detection
0x8013Object recognition
0x8101Positioning device
0x8102ItemURI
SIO mode yes
Necessary master port category A
Supported DeviceIDs>
Mode of operationDeviceID
default1613
Surrounding temperature value[°C] -25...85
Safety feature IP 65; IP 67
Measuring span[mm] 50; (depending on the application)
Minimum field strength[mT] 1

Inputs / outputs

Total count of inputs and outputs Quantity of digital outputs: 2
Voltage for operation[V] 10...30 DC; (cULus - Class 2 source required)
Current draw[mA] < 20
Safety feature rating III
Reverse polarity safeguard yes
Max. power-up delay duration[ms] 300
Output response output signal; IO-Link
Electrical engineering design PNP/NPN; (customizable)
Count of digital outputs 2
Output feature typically open / closed; (customizable)
Max. voltage drop at switching output DC[V] 2.5
Max. stray current[mA] 0.5
Continuous current rating of the switching output DC[mA] 100
DC switching frequency[Hz] 200
Method of overcurrent protection yes (momentary)
Short-circuit resistant yes
Overcurrent protection yes
Hysteresis[mm] 1.25; (customizable)
Reproducibility[mm] < 0.2
Linearity error IO-Link[%] < 5
Definition of detail level[mm] 0,01; (depending on the application)

Download Specification for MK5907

Download PDF