Flow Sensor Ifm SDG450
IFM CATEGORIES
Flow Sensor SDG450
Brand: Ifm
Product Code: SDG3"/METRIS PB DN80
- Accurate measurement of flow and consumption
- Excellent precision, reproducibility, and measurement responsiveness
- For the detection of pressurized air in industrial applications
- Featuring switching output, analog output, and pulse output
- Easily readable numerical display
Product characteristics
| Total count of inputs and outputs | Count of digital outputs: 2; Count of analog outputs: 1 | ||
| Measuring span |
| ||
| Connection for process | flange DN80 in accordance with: DIN EN 10220 | ||
| Application | for commercial applications | ||
| Media | pressurized air | ||
| Intermediate temperature value[°C] | -10...60 | ||
| Minimum force per unit area before bursting |
| ||
| Pressure classification |
| ||
| Precision (within the measurement range) | class 141: ± (3 % MW + 0,3 % MEW); class 344: ± (6 % MW + 0,6 % MEW) ; air quality to ISO 8573-1:2010; reference conditions: inlet pipe length >= 135 cm outlet pipe length >= 19 cm; reference temperature value: 18..26 °C; norm volume flow 12...1539 m³/h; (norm volume flow DIN_ISO_2533 15 °C , 1013,25 mbar, 0 % r.H.) | ||
| Surrounding temperature value[°C] | 0...60 | ||
| Temperature for storage[°C] | -20...85 | ||
| Max. relative humidity of air[%] | 90 | ||
| Safety feature | IP 65; IP 67 |
Reaction times
| Response duration[s] | 0.1; (dAP = 0) |
| Damping process parameter dAP[s] | 0...5 |
| Configuration options | hysteresis / range; typically open / default closed; current/pulse output; display can be rotated and deactivated; display unit; cumulative counter |
| Output response | output signal; analog output; pulse signal; IO-Link; (customizable) |
| Electrical engineering design | PNP/NPN |
| Count of digital outputs | 2 |
| Output feature | typically open / closed; (customizable) |
| Max. voltage drop at switching output DC[V] | 2.5 |
| Continuous current rating of the switching output DC[mA] | 150; (per output) |
| Total analog outputs | 1 |
| Analog current output[mA] | 4...20; (expandable) |
| Max. capacity[O] | 500 |
| Pulse output signal | consumption measurement device |
| Overcurrent protection | yes |
| Method of overcurrent protection | yes (momentary) |
| Overcurrent protection | yes |
Inputs / outputs
| Total count of inputs and outputs | Count of digital outputs: 2; Count of analog outputs: 1 | ||||
| Voltage for operation[V] | 18...30 DC; (to SELV/PELV) | ||||
| Current draw[mA] | < 80 | ||||
| Safety feature rating | III | ||||
| Reverse polarity safeguard | yes | ||||
| Activation delay time[s] | 1 | ||||
| Inputs | reset function | ||||
| Measuring span |
| ||||
| Show range |
| ||||
| In increments of |
| ||||
| communication interface | IO-Link | ||||
| Mode of transmission | COM2 (38,4 kBaud) | ||||
| IO-Link version | 1.1 | ||||
| SDCI specification | IEC 61131-9 CDV | ||||
| Configurations | Digital Measurement Sensor (0x800A), Identification and Diagnostics (0x4000) | ||||
| SIO mode | yes | ||||
| Necessary master port category | A | ||||
| Analog data process | 8 | ||||
| Data binary process | 2 | ||||
| Minimum process cycle duration[ms] | 7.2 | ||||
| Supported DeviceIDs |
|