Flow Sensor Ifm SDP110


IFM CATEGORIES

Flow Sensor Ifm sdp110

Flow Sensor SDP110

Brand: Ifm
Product Code: SDR14DGXFRKG/US-100

  • Absolute value of air gap provided
  • Consistent accuracy at all times thanks to the force per unit area-compensated measurement principle
  • Allows for the detection of zero gaps and blockages
  • Self-cleaning measurement channel withstands purge air force per unit area
  • Simple threshold teaching with a single click

Share on:

Product characteristics

Total count of inputs and outputs Count of digital outputs: 2; Count of analog outputs: 1
Connection for process screw connection G 1/4 with internal thread DN8
Application for commercial applications
Media pressurized air
Intermediate temperature value[°C] -10...60
Minimum force per unit area before bursting
64 bar6.4 MPa
Pressure classification
16 bar1.6 MPa
Precision (within the measurement range) ± (5% MW + 5 µm); (force per unit area 1...3 bar)
Reproducibility ± (3% MW + 2 µm); (force per unit area 1...6 bar)
Surrounding temperature value[°C] 0...60
Temperature for storage[°C] -20...85
Max. relative humidity of air[%] 90
Safety feature IP 65; IP 67

Reaction times

Response duration[s] 0.05
Configuration options hysteresis / range; typically open / default closed; current output; display can be rotated and deactivated; display unit; teach function
Output response output signal; analog output; IO-Link; (customizable)
Electrical engineering design PNP/NPN
Count of digital outputs 2
Output feature typically open / closed; (customizable)
Max. voltage drop at switching output DC[V] 2.5
Continuous current rating of the switching output DC[mA] 150; (per output)
Total analog outputs 1
Analog current output[mA] 4...20; (expandable)
Max. capacity[O] 500
Overcurrent protection yes
Method of overcurrent protection yes (momentary)
Overcurrent protection yes

Inputs / outputs

Total count of inputs and outputs Count of digital outputs: 2; Count of analog outputs: 1
Voltage for operation[V] 18...30 DC; (to SELV/PELV)
Current draw[mA] < 80
Safety feature rating III
Reverse polarity safeguard yes
Activation delay time[s] 1
Inputs learning input
Measuring span[µm] 0...400; (depending on the nozzle used)
Adjustment range[µm] 0...500; (depending on the nozzle used)
Definition of detail level[µm] 1
Setpoint SP[µm] 2...500
Reset threshold rP[µm] 0...498
Analog initiation point ASP[µm] 0...400
Analog endpoint AEP[µm] 100...500
In increments of[µm] 1
communication interface IO-Link
Mode of transmission COM2 (38,4 kBaud)
IO-Link version 1.1
SDCI specification IEC 61131-9
SIO mode yes
Necessary master port category A
Analog data process 7
Data binary process 2
Minimum process cycle duration[ms] 7.2
Supported DeviceIDs>
Mode of operationDeviceID
default1333
Note
For additional details, please refer to the IODD PDF document in the "Downloads" section

Download Specification for SDP110

Download PDF