Flow Sensor Ifm SM6020


IFM CATEGORIES

Flow Sensor Ifm sm6020

Flow Sensor SM6020

Brand: Ifm
Product Code: SMR12XGXFRKG/US-100

  • Accurate monitoring of flow, consumption, and medium temperature value
  • Excellent precision, reproducibility, and measurement responsiveness
  • Featuring switching output, analog output, and pulse output
  • Easily readable color display featuring a red/green color transition
  • No lengths for inlet and outlet pipes are necessary

Share on:

Product characteristics

Total count of inputs and outputs Count of digital outputs: 2; Count of analog outputs: 1
Measuring span
0.05...35 l/min0.003...2.1 m³/h0.6...555 gph0.01...9.25 gpm
Connection for process screw connection G 1/2 with outdoor thread, DN15, and flat seal
System gold-plated terminals
Media Conductive fluids; water; aqueous media
Comment on medium
conductivity: = 20 µS/cm
viscosity: < 70 mm²/s (40 °C)
Intermediate temperature value[°C] -20...90
Pressure classification
16 bar1.6 MPa
Precision (within the measurement range) ± (0,8 % MW + 0,2 % MEW)
Reproducibility ± 0,2 % MEW
Surrounding temperature value[°C] -20...60
Temperature for storage[°C] -25...80
Safety feature IP 65; IP 67

Reaction times

Initialization delay[s] 0...50
Response duration[s] < 0.25; (dAP = 0, T09)
Damping process parameter dAP[s] 0...5
Configuration options hysteresis / band; typically open / default closed; switching method; frequency output; current/pulse output; startup delay; display can be turned off; display module
Overall count of outputs 2
Output response output signal; analog output; pulse signal; IO-Link; frequency signal; (customizable)
Electrical engineering design PNP/NPN
Count of digital outputs 2
Output feature typically open / closed; (customizable)
Max. voltage drop at switching output DC[V] 2
Continuous current rating of the switching output DC[mA] 100
Total analog outputs 1
Analog current output[mA] 4...20; (expandable)
Max. capacity[O] 500
Pulse output signal flow measurement device
Overcurrent protection yes
Method of overcurrent protection yes (momentary)
Overcurrent protection yes

Inputs / outputs

Total count of inputs and outputs Count of digital outputs: 2; Count of analog outputs: 1
Voltage for operation[V] 18...30 DC; (to SELV/PELV)
Current draw[mA] < 80
Safety feature rating III
Reverse polarity safeguard yes
Activation delay time[s] 5
Measuring method magnetic-induction
Inputs reset function
Measuring span
0.05...35 l/min0.003...2.1 m³/h0.6...555 gph0.01...9.25 gpm
Show range
-42...42 l/min-2.5...2.5 m³/h-666...666 gph-11.1...11.1 gpm
Definition of detail level
0.02 l/min0.002 m³/h0.6 gph0.01 gpm
Setpoint SP
0.25...35 l/min0.015...2.1 m³/h4.2...555 gph0.07...9.25 gpm
Reset threshold rP
0...34.8 l/min0...2.08 m³/h1.2...552 gph0.02...9.2 gpm
Analog initiation point ASP
0...28 l/min0...1.7 m³/h0...666 gph0...7.4 gpm
Analog endpoint AEP
7...35 l/min0.42...2.1 m³/h111...555 gph1.85...9.25 gpm
Minimal flow termination LFC
0.05...1.75 l/min0.003...0.1 m³/h0.6...27.6 gph0.01...0.46 gpm
Frequency termination point, FEP
7...35 l/min0.42...2.1 m³/h111.6...555 gph1.86...9.25 gpm
Frequency at termination point FRP[Hz] 1...10000
communication interface IO-Link
Mode of transmission COM2 (38,4 kBaud)
IO-Link version 1.1
SDCI specification IEC 61131-9
Configurations Intelligent Sensor: Data Process Variable; Device Identification; Device Diagnosis
SIO mode yes
Necessary master port category A
Analog data process 3
Data binary process 2
Minimum process cycle duration[ms] 6
Supported DeviceIDs>
Mode of operationDeviceID
default949

Download Specification for SM6020

Download PDF