Flow Sensor Ifm SM9601
IFM CATEGORIES
Flow Sensor SM9601
Brand: Ifm
Product Code: SMN32XGXFRKG/US-100
- Accurate monitoring of flow, consumption, and medium temperature value
- Excellent precision, reproducibility, and measurement responsiveness
- Featuring switching output, analog output, and pulse output
- Easily readable numerical display
Product characteristics
| Total count of inputs and outputs | Count of digital outputs: 2; Count of analog outputs: 1 | ||
| Measuring span |
| ||
| Connection for process | screw connection 1 1/2" NPT with internal threading DN40 | ||
| System | gold-plated terminals | ||
| Application | Cumulative function; detection of empty pipeline; intended for industrial use | ||
| Media | Conductive fluids; water; aqueous media | ||
| Comment on medium |
| ||
| Intermediate temperature value[°F] | 14...194 | ||
| Pressure classification |
| ||
| MAWP (for uses in compliance with CRN)[bar] | 16 | ||
| Precision (within the measurement range) | ± (0,8 % MW + 0,5 % MEW) | ||
| Reproducibility | ± 0,2% MEW | ||
| Surrounding temperature value[°F] | 14...140 | ||
| Temperature for storage[°F] | -13...176 | ||
| Safety feature | IP 65; IP 67 |
Reaction times
| Response duration[s] | 0.35; (dAP = 0) |
| Programmable delay time dS, dr[s] | 0...50 |
| Damping process parameter dAP[s] | 0...5 |
| Configuration options | Flow supervision; volume meter; preset counter; temperature value monitoring; hysteresis / window; typically open / closed; switching logic; current/voltage/frequency/pulse output; startup delay; display can be turned off; display unit; empty pipe detection |
| Overall count of outputs | 2 |
| Output response | output signal; analog output; pulse signal; frequency signal; IO-Link; (customizable) |
| Electrical engineering design | PNP/NPN |
| Count of digital outputs | 2 |
| Output feature | typically open / closed; (customizable) |
| Max. voltage drop at switching output DC[V] | 2 |
| Continuous current rating of the switching output DC[mA] | 250; (per output) |
| Total analog outputs | 1 |
| Analog current output[mA] | 4...20; (expandable) |
| Max. capacity[O] | 500 |
| Analog voltage output[V] | 0...10; (adjustable) |
| Minimum load resistance[O] | 2000 |
| Pulse output signal | flow measurement device |
| Overcurrent protection | yes |
| Method of overcurrent protection | yes (momentary) |
| Overcurrent protection | yes |
| Output frequency[Hz] | 0.1...10000 |
Inputs / outputs
| Total count of inputs and outputs | Count of digital outputs: 2; Count of analog outputs: 1 | ||||
| Voltage for operation[V] | 18...32 DC; (to SELV/PELV) | ||||
| Current draw[mA] | < 150 | ||||
| Safety feature rating | III | ||||
| Reverse polarity safeguard | yes | ||||
| Activation delay time[s] | 5 | ||||
| Measuring method | magnetic-induction | ||||
| Inputs | reset function | ||||
| Measuring span |
| ||||
| Show range |
| ||||
| Definition of detail level |
| ||||
| Setpoint SP |
| ||||
| Reset threshold rP |
| ||||
| Analog initiation point ASP |
| ||||
| Analog endpoint AEP |
| ||||
| Minimal flow termination LFC |
| ||||
| In increments of |
| ||||
| Measurement dynamics | 1:60 | ||||
| communication interface | IO-Link | ||||
| Mode of transmission | COM2 (38,4 kBaud) | ||||
| IO-Link version | 1.1 | ||||
| SDCI specification | IEC 61131-9 CDV | ||||
| Configurations | Intelligent Sensor: Data Process Variable; Device Identification | ||||
| SIO mode | yes | ||||
| Necessary master port category | A | ||||
| Analog data process | 3 | ||||
| Data binary process | 2 | ||||
| Minimum process cycle duration[ms] | 5 | ||||
| Supported DeviceIDs |
|
Download Specification for SM9601