Flow Sensor Ifm SU8200
IFM CATEGORIES
Flow Sensor SU8200
Brand: Ifm
Product Code: SUR11HGBFPKG/W/US-100-IPF
- Consistent monitoring of flow and medium temperature value
- Compatible with water, oils, and glycol-based solutions
- Designed for installation within pipes
- Featuring two programmable switching outputs
- Easily readable numerical display
Product characteristics
| Total count of inputs and outputs | Quantity of digital outputs: 2 | ||
| Measuring span |
| ||
| Connection for process | screw connection G 1 with outdoor thread flat seal | ||
| System | gold-plated terminals | ||
| Application | for commercial applications | ||
| Setup | connection to pipe via an adapter | ||
| Media | water; glycol mixtures; coolants; oils | ||
| Comment on medium |
| ||
| Intermediate temperature value[°C] | -10...80 | ||
| Pressure classification |
| ||
| Response duration[s] | 0.25; (dAP = 0) | ||
| Programmable delay time dS, dr[s] | 0...50 | ||
| Damping process parameter dAP[s] | 0...1 | ||
| Weight[g] | 1694 | ||
| Housing | rectangular shape | ||
| measurements[mm] | 130 x 100 x 80.5 | ||
| Substance | enclosure: anodized AlMgSi0.5; sealing: FKM; PA 6.6; protective film: PA | ||
| Substances (contacted components) | stainless steel (1.4404 / 316L); FKM; PES; Centellen 200 | ||
| Connection for process | screw connection G 1 with outdoor thread flat seal |
Software / programming
| Configuration options | Flow detection; Temperature supervision | ||
| Surrounding temperature value[°C] | -10...60 | ||
| Temperature for storage[°C] | -25...80 | ||
| Safety feature | IP 67 | ||
| Measuring span |
| ||
| Show range |
| ||
| Definition of detail level |
| ||
| Setpoint SP |
| ||
| Reset threshold rP |
| ||
| Max. maximum flow rate[l/min] | 110 | ||
| In increments of |
|
Inputs / outputs
| Total count of inputs and outputs | Quantity of digital outputs: 2 |
| Voltage for operation[V] | 19...30 DC; (to SELV/PELV) |
| Current draw[mA] | 100 |
| Minimum insulation resistance[MO] | 100; (500 V DC) |
| Safety feature rating | III |
| Reverse polarity safeguard | yes |
| Activation delay time[s] | 10 |
| Measuring method | ultrasonics |
| Overall count of outputs | 2 |
| Output response | output signal |
| Electrical engineering design | PNP |
| Count of digital outputs | 2 |
| Output feature | typically open / closed; (customizable) |
| Max. voltage drop at switching output DC[V] | 2 |
| Continuous current rating of the switching output DC[mA] | 250; (per output) |
| Overcurrent protection | yes |
| Method of overcurrent protection | yes (momentary) |
| Overcurrent protection | yes |
| Precision (within the measurement range) | water: < ± (3 % MW + 0.2 % MEW); glycol (35 %), oil (viscosity 68 mm²/s at 40 °C): < ± (5 % MW + 0.5 % MEW) |
| Reproducibility | 0,2 l/min (0,05 gpm) |