Inductive Sensor Ifm II001A
IFM CATEGORIES
Inductive Sensor II001A
Brand: Ifm
Product Code: IIA2015-ABOA/6M/3D
- Suitable for use in hazardous environments
- With AC/ DC combined output
- Wide operating voltage range
- Two-conductor technology
- Durable metal enclosure designed for harsh industrial conditions
Product characteristics
| Output feature | typically open | ||
| Detection range[mm] | 15 | ||
| Housing | Screw-type | ||
| measurements[mm] | M30 x 1.5 / L = 81 | ||
| Setup | apply in hazardous locations only with protective cover installed | ||
| Items provided |
|
Mechanical data
| Weight[g] | 489 | ||
| Housing | Screw-type | ||
| Installation | non-recessed mountable | ||
| measurements[mm] | M30 x 1.5 / L = 81 | ||
| Thread specification | M30 x 1.5 | ||
| Substance | brass white bronze plated; sensing surface: PBT; locknuts: brass white bronze plated; protective cover: PA | ||
| Display |
| ||
| Adjustment coefficient | steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminum: 0.3 / copper: 0.2 | ||
| Hysteresis[% of Sr] | 1...20 | ||
| Setting-point drift[% of Sr] | -10...10 |
Outputs
| Output feature | typically open | |
| Max. voltage drop at switching output DC[V] | 6 | |
| Max. voltage drop at switching output AC[V] | 6.5 | |
| Minimum load current[mA] | 5 | |
| Max. stray current[mA] | 2.5 (250 V AC) / 1.3 (130 V AC) / 0.8 (24 V DC) | |
| Continuous current rating of the switching output AC[mA] | 150 | |
| Continuous current rating of the switching output DC[mA] | 100 | |
| Momentary current capacity of switching output[mA] | 2200; (20 ms / 0,5 Hz) | |
| AC switching frequency[Hz] | 25 | |
| DC switching frequency[Hz] | 50 | |
| Observations regarding switching frequency[Hz] |
| |
| Overcurrent protection | no | |
| Overcurrent protection | no | |
| Voltage for operation[V] | 20...250 AC/DC | |
| Safety feature rating | II | |
| Reverse polarity safeguard | yes | |
| Detection range[mm] | 15 | |
| Actual sensing range Sr[mm] | 15 ± 10 % | |
| Operational range[mm] | 0...12.1 | |
| Surrounding temperature value[°C] | -20...60 | |
| Safety feature | IP 67 | |
| Necessary safeguarding | miniature fuse in accordance with IEC60127-2 sheet 1; = 2 A; quick acting; Install the fuse beyond the hazardous zone |
Download Specification for II001A
Download PDFRELATED PRODUCTS