Pressure Sensor Ifm PI1703


IFM CATEGORIES

Pressure Sensor Ifm pi1703

Pressure Sensor PI1703

Brand: Ifm
Product Code: PI-025-REA01-MFRKG/US/ /P

  • Durable stainless steel construction to meet the demands of the food and beverage sector
  • Sanitary, flush-mounted design
  • Durable against high-force per unit area washing using harsh cleaning chemicals
  • Excellent resistance to elevated temperature values and elevated protection rating
  • Configurable analog and switching output

Share on:

Product characteristics

Total count of inputs and outputs Count of digital outputs: 2; Count of analog outputs: 1
Measuring span
-1...25 bar-14.5...362.5 psi-0.1...2.5 MPa
Connection for process screw connection G 1 with outdoor thread Aseptoflex Vario
System gold-plated terminals
Application recessed installation compatible for the food and drink sector
Media viscous substances and fluids with suspended particulates; fluids and gases
Intermediate temperature value[°C] -25...150
Minimum force per unit area before bursting
350 bar5075 psi35 MPa
Pressure classification
100 bar1450 psi10 MPa
Vacuum strength
-1000 mbar-0.1 MPa
Kind of force per unit area relative force per unit area; vacuum
No unused space yes
MAWP (for uses in compliance with CRN)[bar] 61
Damping process parameter dAP[s] 0...99.99
Damping for the analog output dAA[s] 0...99.99
Weight[g] 358.2
Housing cylindrical
measurements[mm] Ø 50 / L = 107
Substance stainless steel (1.4404 / 316L); FKM; PTFE; PBT; PEI; PFA
Substances (contacted components) ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface features: Ra < 0.4 / Rz 4; PTFE
Minimum force per unit area cycles 100 million
Fastening torque[Nm] 35
Connection for process screw connection G 1 with outdoor thread Aseptoflex Vario

Interfaces

communication interface IO-Link
Mode of transmission COM2 (38,4 kBaud)
IO-Link version 1.1
SDCI specification IEC 61131-9
Configurations
Operation classOverview
0x4000Identification and Fault Detection
0x800AMeasurement data channel (norm accuracy)
SIO mode yes
Necessary master port category A
Minimum process cycle duration[ms] 5.6
IO-Link force per unit area accuracy[bar] 0.001
IO-Link temperature value resolution[K] 0.2
IO-Link cyclic process data
Operationbit length
force per unit area32
temperature value32
device status4
two-state switching data2
IO-Link acyclical functions application-specific label; internal temperature value; runtime counter; switching cycle meter; force per unit area peak meter
Supported DeviceIDs>
Mode of operationDeviceID
default1157
Surrounding temperature value[°C] -25...80
Temperature for storage[°C] -40...100
Safety feature IP 67; IP 68; IP 69K
Measuring span
-1...25 bar-14.5...362.5 psi-0.1...2.5 MPa
Setpoint SP
-0.96...25 bar-14...362.6 psi-0.096...2.5 MPa
Reset threshold rP
-1...24.96 bar-14.5...362.1 psi-0.1...2.496 MPa
Analog initiation point
-1...20 bar-14.5...290.1 psi-0.1...2 MPa
Analog endpoint
4...25 bar58...362.6 psi0.4...2.5 MPa
Minimum difference between set point (SP) and reference point (rP)
0.04 bar0.6 psi0.004 MPa
In increments of
0.01 bar0.1 psi0.001 MPa
default configuration
SP1 = 6.25 barrP1 = 5.75 bar
SP2 = 18.75 barrP2 = 18.25 bar
ASP = 0.00 barAEP = 25.00 bar
dAP = 0.06 sdAA = 0.06 s

Inputs / outputs

Total count of inputs and outputs Count of digital outputs: 2; Count of analog outputs: 1
Minimum insulation resistance[MO] 100; (500 V DC)
Safety feature rating III
Reverse polarity safeguard yes
Built-in watchdog yes
Overall count of outputs 2
Output response output signal; analog output; IO-Link
Electrical engineering design PNP/NPN
Count of digital outputs 2
Output feature typically open / closed; (customizable)
Total analog outputs 1
Analog current output[mA] 4...20, invertible; (expandable)
Overcurrent protection yes
Method of overcurrent protection yes (momentary)
Overcurrent protection yes
Precision of switch points/span>[% of the span] < ± 0,2; (DIN EN IEC 62828-1; Turn down 1:1)
Reproducibility[% of the span] < ± 0,1; (with temperature value fluctuations < 10 K; Turn down 1:1)
Characteristics variation[% of the span] < ± 0,2; (DIN IEC EN 62828-1 incl. zero point and span error, non-linearity, hysteresis; Turn down 1:1)
Linearity variation[% of the span] < ± 0,15; (Turn down 1:1)
Hysteresis variation[% of the span] < ± 0,15; (Turn down 1:1)
Extended stability[% of the span] < ± 0,1; (Turn down 1:1; per year)
Overall deviation across temperature value range
Operating temperature value rangeoverall deviation
-25...15 °CCharacteristics variation ± 0.05 % of the span / 10 K
15...80 °CCharacteristics variation
80...150 °CCharacteristics variation ± 0.1 % of the span / 10 K
Comments on the precision / variation for additional information refer to the section Diagrams and graphs

Download Specification for PI1703

Download PDF

RELATED PRODUCTS