Pressure Sensor Ifm PN016A


IFM CATEGORIES

Pressure Sensor Ifm pn016a

Pressure Sensor PN016A

Brand: Ifm
Product Code: PN-2,5-RBR14-QFPKG/US/3D /V

  • Suitable for use in hazardous environments
  • Dual switching outputs, with one that can be set as a diagnostic output
  • Easily readable numerical display
  • Durable stainless steel enclosure designed for demanding industrial settings
  • Service life exceeding 100 million force per unit area cycles

Share on:

Product characteristics

Total count of inputs and outputs Quantity of digital outputs: 2
Measuring span
0...2.5 bar0...2500 mbar0...36.3 psi0...250 kPa
Connection for process screw connection G 1/4 with internal threading
System gold-plated terminals
Application for commercial applications
Media fluids and gases
Intermediate temperature value[°C] -20...60
Minimum force per unit area before bursting
50 bar725 psi5000 kPa
Pressure classification
20 bar290 psi2000 kPa
Kind of force per unit area relative force per unit area
Programmable delay time dS, dr[s] 0; 0,2...50

Software / programming

Configuration options hysteresis / range; typically open / default closed; diagnostic function; switching method; switch-on/switch-off delay; damping; display unit
communication interface IO-Link
Mode of transmission COM2 (38,4 kBaud)
IO-Link version 1.1
SDCI specification IEC 61131-9 CDV
Configurations without profile
SIO mode yes
Necessary master port category A
Analog data process 1
Data binary process 2
Minimum process cycle duration[ms] 2.3
Supported DeviceIDs>
Mode of operationDeviceID
default312
Measuring span
0...2.5 bar0...2500 mbar0...36.3 psi0...250 kPa
Setpoint SP
0.02...2.5 bar0.4...36.2 psi2...250 kPa
Reset threshold rP
0.01...2.49 bar0.2...36 psi1...249 kPa
In increments of
0.01 bar0.2 psi1 kPa
default configuration
SP1 = 0.63 barrP1 = 0.58 bar
SP2 = 1.88 barrP2 = 1.83 bar

Inputs / outputs

Total count of inputs and outputs Quantity of digital outputs: 2
Voltage for operation[V] 18...36 DC; (to SELV/PELV)
Current draw[mA] < 50
Safety feature rating III
Reverse polarity safeguard yes
Voltage surge protection yes; (< 40 V)
Activation delay time[s] 0.3
Built-in watchdog yes
Overall count of outputs 2
Output response output signal; IO-Link; (customizable)
Electrical engineering design PNP/NPN
Count of digital outputs 2
Output feature typically open / closed; (customizable)
Max. voltage drop at switching output DC[V] 2
Continuous current rating of the switching output DC[mA] 250
DC switching frequency[Hz] < 170
Overcurrent protection yes
Method of overcurrent protection yes (momentary)
Precision of switch points/span>[% of the span] < ± 0,5
Reproducibility[% of the span] < ± 0,1; (with temperature value fluctuations < 10 K)
Characteristics variation[% of the span] < ± 0.25 (BFSL) / < ± 0.5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis variation[% of the span] < ± 0,25
Extended stability[% of the span] < ± 0,05; (per 6 months)
Temperature coefficient value for the zero reference[% of the span / 10 K] 0,2; (0...60 °C)
Temperature coefficient value for the range[% of the span / 10 K] 0,2; (0...60 °C)
Surrounding temperature value[°C] -20...60
Temperature for storage[°C] -40...100
Safety feature IP 65

Download Specification for PN016A

Download PDF

RELATED PRODUCTS