Pressure Sensor Ifm PQ3809
IFM CATEGORIES
Pressure Sensor PQ3809
Brand: Ifm
Product Code: PQ-1-1-KHR18-KFPKG/AS/
- Consistent monitoring of system force per unit area in pneumatic and pressurized air systems
- Extremely high resistance to overforce per unit area and vacuum
- Easily readable angled LED display
- Red/green indicator for easy recognition of the acceptable range
- Equipped with a programmable switching output and an analog output
Product characteristics
| Total count of inputs and outputs | Total digital outputs: 1; Total analog outputs: 1 | |||||
| Measuring span |
| |||||
| Connection for process | screw connection G 1/8 with internal thread and internal thread: M5 | |||||
| System | gold-plated terminals | |||||
| Application | for commercial applications | |||||
| Potentially appropriate for | additional media available upon request | |||||
| Intermediate temperature value[°C] | 0...60 | |||||
| Minimum force per unit area before bursting |
| |||||
| Comment on minimum burst force per unit area |
| |||||
| Pressure classification |
| |||||
| Vacuum strength |
| |||||
| Kind of force per unit area | relative force per unit area; differential force per unit area; vacuum | |||||
| Response duration[ms] | < 6 | |||||
| Programmable delay time dS, dr[s] | 0; 0,002...5 | |||||
| Step response duration for analog output[ms] | 6 |
Software / programming
| Configuration options | hysteresis / range; typically open / default closed; analog output; IO-Link; switching method; switch-on/switch-off delay; damping; display unit | |||||
| communication interface | IO-Link | |||||
| Mode of transmission | COM2 (38,4 kBaud) | |||||
| IO-Link version | 1.1 | |||||
| SDCI specification | IEC 61131-9 FDIS | |||||
| Configurations | Intelligent Sensor: Data Process Variable; Device Identification | |||||
| SIO mode | yes | |||||
| Necessary master port category | A | |||||
| Analog data process | 1 | |||||
| Data binary process | 2 | |||||
| Minimum process cycle duration[ms] | 2.3 | |||||
| Supported DeviceIDs |
| |||||
| Measuring span |
| |||||
| Setpoint SP |
| |||||
| Reset threshold rP |
| |||||
| In increments of |
|
Inputs / outputs
| Total count of inputs and outputs | Total digital outputs: 1; Total analog outputs: 1 |
| Voltage for operation[V] | 18...32 DC; (to SELV/PELV) |
| Current draw[mA] | < 50 |
| Minimum insulation resistance[MO] | 100; (500 V DC) |
| Safety feature rating | III |
| Reverse polarity safeguard | yes |
| Voltage surge protection | yes; (< 40 V) |
| Activation delay time[s] | 0.5 |
| Built-in watchdog | yes |
| Overall count of outputs | 2 |
| Output response | output signal; analog output; IO-Link; (customizable) |
| Electrical engineering design | PNP |
| Count of digital outputs | 1 |
| Output feature | typically open / closed; (customizable) |
| Max. voltage drop at switching output DC[V] | 2 |
| Continuous current rating of the switching output DC[mA] | 100 |
| DC switching frequency[Hz] | < 100 |
| Total analog outputs | 1 |
| Analog current output[mA] | 4...20 |
| Max. capacity[O] | 500 |
| Overcurrent protection | yes |
| Method of overcurrent protection | yes (momentary) |
| Precision of switch points/span>[% of the span] | < ± 0,5 |
| Reproducibility[% of the span] | < ± 0,1; (with temperature value fluctuations < 10 K) |
| Characteristics variation[% of the span] | < ± 0.25 (BFSL) / < ± 0.5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
| Hysteresis variation[% of the span] | < ± 0,25 |
| Extended stability[% of the span] | < ± 0,05; (per 6 months) |
| Temperature coefficient value for the zero reference[% of the span / 10 K] | 0,2; (0...60 °C) |
| Temperature coefficient value for the range[% of the span / 10 K] | 0,2; (0...60 °C) |
| Surrounding temperature value[°C] | 0...70 |
| Temperature for storage[°C] | -25...85 |
| Safety feature | IP 65 |
Download Specification for PQ3809