Pressure Sensor Ifm PQ7809
IFM CATEGORIES
Pressure Sensor PQ7809
Brand: Ifm
Product Code: PQ-1-1-RHR18-QFPKG/AS/
- Consistent monitoring of system force per unit area in pneumatic and pressurized air systems
- Extremely high resistance to overforce per unit area and vacuum
- Easily readable angled LED display
- Red/green indicator for easy recognition of the acceptable range
- Dual switching outputs, with one that can be set as a diagnostic output
Product characteristics
| Total count of inputs and outputs | Quantity of digital outputs: 2 | |||||
| Measuring span |
| |||||
| Connection for process | screw connection G 1/8 with internal thread | |||||
| System | gold-plated terminals | |||||
| Application | for commercial applications | |||||
| Media | pressurized air | |||||
| Potentially appropriate for | additional media available upon request | |||||
| Intermediate temperature value[°C] | 0...60 | |||||
| Minimum force per unit area before bursting |
| |||||
| Pressure classification |
| |||||
| Vacuum strength |
| |||||
| Kind of force per unit area | relative force per unit area; vacuum | |||||
| Response duration[ms] | < 2.5 | |||||
| Programmable delay time dS, dr[s] | 0; 0,002...5 | |||||
| Weight[g] | 85 | |||||
| Housing | rectangular shape | |||||
| measurements[mm] | 42 x 30 x 32 | |||||
| Substance | PBT; FKM; polyester | |||||
| Substances (contacted components) | brass; FKM; silicone (coated); PBT | |||||
| Minimum force per unit area cycles | 50 million | |||||
| Connection for process | screw connection G 1/8 with internal thread |
Software / programming
| Configuration options | hysteresis / range; typically open / default closed; diagnostic function; switching method; switch-on/switch-off delay; damping; display unit | |||||
| Surrounding temperature value[°C] | 0...70 | |||||
| Temperature for storage[°C] | -25...85 | |||||
| Safety feature | IP 65 | |||||
| Measuring span |
| |||||
| Setpoint SP |
| |||||
| Reset threshold rP |
| |||||
| In increments of |
|
Inputs / outputs
| Total count of inputs and outputs | Quantity of digital outputs: 2 |
| Voltage for operation[V] | 18...32 DC; (to SELV/PELV) |
| Current draw[mA] | < 50 |
| Minimum insulation resistance[MO] | 100; (500 V DC) |
| Safety feature rating | III |
| Reverse polarity safeguard | yes |
| Voltage surge protection | yes; (< 40 V) |
| Activation delay time[s] | 0.3 |
| Built-in watchdog | yes |
| Overall count of outputs | 2 |
| Output response | output signal |
| Electrical engineering design | PNP |
| Count of digital outputs | 2 |
| Output feature | typically open / closed; (customizable) |
| Max. voltage drop at switching output DC[V] | 2 |
| Continuous current rating of the switching output DC[mA] | 100 |
| DC switching frequency[Hz] | < 200 |
| Overcurrent protection | yes |
| Method of overcurrent protection | yes (momentary) |
| Precision of switch points/span>[% of the span] | < ± 0,5 |
| Reproducibility[% of the span] | < ± 0,1; (with temperature value fluctuations < 10 K) |
| Characteristics variation[% of the span] | < ± 0.25 (BFSL) / < ± 0.5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
| Hysteresis variation[% of the span] | < ± 0,25 |
| Extended stability[% of the span] | < ± 0,05; (per 6 months) |
| Temperature coefficient value for the zero reference[% of the span / 10 K] | 0,2; (0...60 °C) |
| Temperature coefficient value for the range[% of the span / 10 K] | 0,2; (0...60 °C) |
Download Specification for PQ7809
Download PDFRELATED PRODUCTS