Pressure Sensor Ifm PY2007
IFM CATEGORIES
Pressure Sensor PY2007
Brand: Ifm
Product Code: PM-001BREA01 -E-ZVG/US
- Durable stainless steel enclosure designed for applications in the food and drink sector
- Sanitary, flush-mounted design
- Durable against high-force per unit area washing using harsh cleaning chemicals
- Excellent resistance to elevated temperature values and elevated protection rating
Product characteristics
| Total count of inputs and outputs | Count of analog outputs: 1 | |||
| Measuring span |
| |||
| Connection for process | screw connection G 1 with outdoor thread Aseptoflex Vario | |||
| System | gold-plated terminals | |||
| Sensing element | ceramic capacitive force per unit area sensing element | |||
| Application | recessed installation compatible for the food and drink sector | |||
| Media | viscous substances and fluids with suspended particulates; fluids and gases | |||
| Intermediate temperature value[°C] | -25...85; (125: < 1 h) | |||
| Minimum force per unit area before bursting |
| |||
| Pressure classification |
| |||
| Vacuum tolerance[mbar] | -1000 | |||
| Kind of force per unit area | relative force per unit area | |||
| No unused space | yes | |||
| MAWP (for uses in compliance with CRN)[bar] | 10 | |||
| Damping for the analog output dAA[s] | 0...4 | |||
| Weight[g] | 555.8 | |||
| Housing | cylindrical | |||
| measurements[mm] | Ø 34 / L = 186.4 | |||
| Substance | stainless steel (1.4404 / 316L); stainless steel (1.4301 / 304); PBT | |||
| Substances (contacted components) | ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra 0,4 / Rz 4; PTFE | |||
| Minimum force per unit area cycles | 100 million | |||
| Fastening torque[Nm] | 35 | |||
| Connection for process | screw connection G 1 with outdoor thread Aseptoflex Vario |
Interfaces
| communication interface | IO-Link | |||
| Mode of transmission | COM2 (38,4 kBaud) | |||
| IO-Link version | 1.1 | |||
| Configurations | Digital Measurement Sensor (0x000A), Identification and Diagnostic (0x4000) | |||
| SIO mode | no | |||
| Necessary master port category | A | |||
| Analog data process | 3 | |||
| Minimum process cycle duration[ms] | 3.2 | |||
| Surrounding temperature value[°C] | -25...80 | |||
| Temperature for storage[°C] | -40...100 | |||
| Safety feature | IP 67; IP 68; IP 69K | |||
| Measuring span |
| |||
| Analog initiation point |
| |||
| Analog endpoint |
| |||
| In increments of |
| |||
| default configuration |
|
Inputs / outputs
| Total count of inputs and outputs | Count of analog outputs: 1 | ||||||||
| Voltage for operation[V] | 18...30 DC | ||||||||
| Minimum insulation resistance[MO] | 100; (500 V DC) | ||||||||
| Safety feature rating | III | ||||||||
| Reverse polarity safeguard | yes | ||||||||
| Measuring method | hydrostatic | ||||||||
| Built-in watchdog | yes | ||||||||
| Overall count of outputs | 1 | ||||||||
| Output response | analog signal; (customizable) | ||||||||
| Total analog outputs | 1 | ||||||||
| Analog current output[mA] | 4...20; (expandable) | ||||||||
| Max. capacity[O] | 700; (Ub = 24 V; (Ub - 9 V) / 21.5 mA) | ||||||||
| Short-circuit resistant | yes | ||||||||
| Overcurrent protection | yes | ||||||||
| Reproducibility[% of the span] | < ± 0,1; (with temperature value fluctuations < 10 K; Turn down 1:1) | ||||||||
| Characteristics variation[% of the span] | < ± 0,2; (linearity incl. hysteresis and repeatability, limit value setting to DIN EN IEC 62828-1) | ||||||||
| Linearity variation[% of the span] | < ± 0,15; (Turn down 1:1) | ||||||||
| Hysteresis variation[% of the span] | < ± 0,15; (Turn down 1:1) | ||||||||
| Extended stability[% of the span] | < ± 0,1; (Turn down 1:1; per year) | ||||||||
| Overall deviation across temperature value range |
| ||||||||
| Comments on the precision / variation | for additional information refer to the section Diagrams and graphs |
Download Specification for PY2007