Pressure Sensor Ifm PY2033


IFM CATEGORIES

Pressure Sensor Ifm py2033

Pressure Sensor PY2033

Brand: Ifm
Product Code: PN-025-RDR12-MFRKG/US/ /V

  • Dual switching outputs, with one configured as an analog output
  • Easily readable numerical display
  • Selectable force per unit area units specific to each country
  • Features long-term stability due to robust overload protection
  • Configurable output polarity

Share on:

Product characteristics

Total count of inputs and outputs Count of digital outputs: 2; Count of analog outputs: 1
Measuring span
-1...25 bar-14.5...362.5 psi-0.1...2.5 MPa
Connection for process screw connection G 1/2 with outdoor thread
System gold-plated terminals
Application Industrial flush-mounted force per unit area signal generators, analog | PL; intended for commercial applications
Media fluids and gases
Intermediate temperature value[°C] -20...125
Minimum force per unit area before bursting
200 bar2900 psi20 MPa
Pressure classification
100 bar1450 psi10 MPa
Kind of force per unit area relative force per unit area
No unused space yes
Response duration[ms] < 1.5
Damping process parameter dAP[s] 0.01...4
Damping for the analog output dAA[s] 0.01...4
Max. response duration for analog output[ms] 3
Weight[g] 390
Housing cylindrical
measurements[mm] Ø 34 / L = 123.2
Substance stainless steel (1.4301 / 304); stainless steel (1.4435 / 316L); polycarbonate (PC); polybutylene terephthalate (PBT); polyetherimide (PEI); polytetrafluoroethylene (PTFE)
Substances (contacted components) stainless steel (1.4435 / 316L)
Minimum force per unit area cycles 10 million
Connection for process screw connection G 1/2 with outdoor thread
Transfer fluid for force per unit area transmission NEOBEE (food-safe, FDA approved)

Software / programming

Configuration options hysteresis / range; typically open / default closed; switching method; current/voltage output; damping; adjustment of displayed values; display can be rotated and deactivated; display module; zero point; span
Surrounding temperature value[°C] -25...80
Temperature for storage[°C] -40...100
Safety feature IP 65
Measuring span
-1...25 bar-14.5...362.5 psi-0.1...2.5 MPa
Setpoint SP
-0.8...25 bar-11.5...362.5 psi-0.08...2.5 MPa
Reset threshold rP
-0.9...24.9 bar-13...361 psi-0.09...2.49 MPa
Analog initiation point
-1...18.75 bar-14.5...272 psi-0.1...1.88 MPa
Analog endpoint
5.25...25 bar76...362.5 psi0.53...2.5 MPa
In increments of
0.05 bar0.5 psi0.01 MPa
default configuration
SP1 = 6.25 barrP1 = 5.75 bar
SP2 = 18.75 barrP2 = 18.25 bar
ASP = 0.00 barAEP = 25.00 bar

Inputs / outputs

Total count of inputs and outputs Count of digital outputs: 2; Count of analog outputs: 1
Voltage for operation[V] 18...32 DC; (to SELV/PELV)
Current draw[mA] < 35
Minimum insulation resistance[MO] 100; (500 V DC)
Safety feature rating III
Reverse polarity safeguard yes
Activation delay time[s] 0.3
Built-in watchdog yes
Overall count of outputs 2
Output response output signal; analog output; (customizable)
Electrical engineering design PNP/NPN
Count of digital outputs 2
Output feature typically open / closed; (customizable)
Max. voltage drop at switching output DC[V] 2
Continuous current rating of the switching output DC[mA] 250
DC switching frequency[Hz] < 500
Total analog outputs 1
Analog current output[mA] 4...20; (modifiable 1:4)
Max. capacity[O] (Ub - 10 V) / 20 mA
Analog voltage output[V] 0...10; (flexible 1:4)
Minimum load resistance[O] 2000
Overcurrent protection yes
Method of overcurrent protection yes (momentary)
Overcurrent protection yes
Precision of switch points/span>[% of the span] < ± 0,4; (Turn down 1:1)
Reproducibility[% of the span] < ± 0,1; (with temperature value fluctuations < 10 K; Turn down 1:1)
Characteristics variation[% of the span] < ± 0,3 (BFSL) / < ± 0,6 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting)
Linearity variation[% of the span] < ± 0,5; (Turn down 1:1)
Hysteresis variation[% of the span] < ± 0,1; (Turn down 1:1)
Extended stability[% of the span] < ± 0,1; (Turn down 1:1; per year)
Temperature coefficient value for the zero reference[% of the span / 10 K] < ± 0,25; (0...80 °C)
Temperature coefficient value for the range[% of the span / 10 K] < ± 0,25; (0...80 °C)