Inductive Sensor Pepperl+Fuchs NBB4-12GM50-E2-V1-3G-3D
Pepperl+Fuchs Categories
Inductive Sensor NBB4-12GM50-E2-V1-3G-3D
Brand: Pepperl+Fuchs
Product Code:
Datasheet excerpt: Technical data of NBB4-12GM50-E2-V1-3G-3D
| Overall specifications | ||
|---|---|---|
| transition function | normally open (NO) | |
| Output configuration | PNP | |
| Specified functioning distance | 4 mm | |
| mounting | flush | |
| Output configuration | DC | |
| Guaranteed functioning distance | 0 ... 3.24 mm | |
| diminution factor rAl | 0.45 | |
| diminution factor rCu | 0.35 | |
| diminution factor r304 | 0.7 | |
| Output configuration | 3-wire | |
| Rated specifications | ||
| Operational voltage | 10 ... 30 V DC | |
| commutation frequency | 0 ... 1000 Hz | |
| Deadband | typ. 5 % | |
| Polarity reversal protection | reverse polarity safeguarded | |
| Overcurrent protection | pulsing | |
| voltage loss | = 3 V | |
| Operational current | 0 ... 150 mA | |
| Non-conducting current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
| Non-conducting current IU =40 °C, deactivating the switching element | = | |
| No-load input current | = 15 mA | |
| Delay time prior to availability | = 5 ms | |
| State indication for switching | Yellow multihole LED | |
| Parameters related to functional safety | ||
| MTTFd | 1820 a | |
| task duration (TM) | 20 a | |
| Diagnostic Range (DC) | 0 % | |
| Adherence to standards and directives | ||
| Compliance with standards | ||
| Standards | EN IEC 60947-5-2 | |
| Certifications and approvals | ||
| IECEx certification | ||
| Equipment protection rating Gc (ec) | IECEx TUR 21.0017X | |
| Equipment protection rating Dc (tc) | IECEx TUR 21.0018X | |
| ATEX certification | ||
| Equipment protection rating Gc (ec) | TÜV 20 ATEX 8523 X | |
| Equipment protection rating Dc (tc) | TÜV 20 ATEX 8524 X | |
| UL certification | cULus Certified, Standard Use | |
| Marine certification | DNVGL TAA0000160 | |
| Environmental conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical characteristics | ||
| Linkage method | plug connector M12 x 1, 4-contact | |
| Cable version | PBT | |
| Housing material | brass with a nickel coating | |
| detection surface | PBT | |
| Protection等级 | IP67 | |
| Measurements | ||
| Length | 49 mm | |
| Diameter | 12 mm | |
| Overview information | ||
| Usage in hazardous environments | refer to instruction manuals | |
Classifications
| Configuration | Classification code |
|---|---|
| ECLASS 13.0 | 27274001 |
| ECLASS 12.0 | 27274001 |
| ECLASS 11.0 | 27270101 |
| ECLASS 10.0.1 | 27270101 |
| ECLASS 9.0 | 27270101 |
| ECLASS 8.0 | 27270101 |
| ECLASS 5.1 | 27270101 |
| ETIM 9.0 | EC002714 |
| ETIM 8.0 | EC002714 |
| ETIM 7.0 | EC002714 |
| ETIM 6.0 | EC002714 |
| ETIM 5.0 | EC002714 |
| UNSPSC 12.1 | 39121550 |
Download Specification for NBB4-12GM50-E2-V1-3G-3D