Datasheet excerpt: Technical data of PL3-F25-N4-K
| Overall specifications | ||
|---|---|---|
| transition function | 2 x normally closed (NC) | |
| Output configuration | NAMUR | |
| Specified functioning distance | 3 mm | |
| mounting | surface mountable | |
| Guaranteed functioning distance | 0 ... 2.43 mm | |
| Actual sensing distance | 2.7 ... 3.3 mm | |
| diminution factor rAl | 0.52 | |
| diminution factor rCu | 0.43 | |
| diminution factor r304 | 0.86 | |
| diminution factor rSt37 | 1 | |
| diminution factor rBrass | 0.54 | |
| Output configuration | 2-wire | |
| Rated specifications | ||
| nominal voltage | 8.2 V (Ri approximately 1 kΩ | |
| Operational voltage | 5 ... 25 V | |
| commutation frequency | 0 ... 100 Hz | |
| Deadband | typ. 5 % | |
| Polarity reversal protection | reverse polarity safeguarded | |
| Overcurrent protection | yes | |
| Compatible with 2:1 technology | yes, reverse polarity protection diode is unnecessary | |
| Current draw | ||
| Measurement plate not found | = 3 mA at nominal voltage | |
| Measuring plate identified | = 1 mA at nominal voltage | |
| Delay time prior to availability | = 1 ms | |
| State indication for switching | LED, yellow | |
| Valve status indicator | LED, yellow can be disabled by DB1 |
|
| Parameters related to functional safety | ||
| MTTFd | 834 a | |
| task duration (TM) | 20 a | |
| Diagnostic Range (DC) | 0 % | |
| Adherence to standards and directives | ||
| Compliance with standards | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
|
| Electromagnetic interference compliance | NE 21:2007 | |
| Standards | EN IEC 60947-5-2 | |
| Certifications and approvals | ||
| IECEx certification | ||
| Equipment protection rating Ga | IECEx TUN 17.0021X | |
| Equipment protection rating Gb | IECEx TUN 17.0021X | |
| Equipment protection rating Mb | IECEx TUN 17.0021X | |
| ATEX certification | ||
| Equipment protection rating Ga | TÜV 99 ATEX 1479 X | |
| Equipment protection rating Gb | TÜV 99 ATEX 1479 X | |
| Equipment protection rating Gc (ic) | PF13CERT2895 X | |
| CCC certification | ||
| explosive atmosphere | 2020322315002262 | |
| NEPSI certification | ||
| NEPSI accreditation | GYJ19.1410X | |
| Environmental conditions | ||
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
| Ambient storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical characteristics | ||
| Connection point (system side) | Cage spring terminals for tension adjustment | |
| cross section of the core (system side) | up to 2.5 mm2 | |
| Linkage (actuator side) | Cage spring terminals for tension adjustment | |
| Core cross-section (valve side) | up to 2.5 mm2 | |
| Housing material | PBT | |
| detection surface | PBT | |
| Mass | 91 g | |
| Fastening torque for securing screws | 0.3 Nm | |
| Measurements | ||
| Height | 99 mm | |
| Width | 67 mm | |
| Length | 34 mm | |
| Overview information | ||
| Usage in hazardous environments | refer to instruction manuals | |
Classifications
| Configuration | Classification code |
|---|---|
| ECLASS 13.0 | 27273901 |
| ECLASS 12.0 | 27273901 |
| ECLASS 11.0 | 27220501 |
| ECLASS 10.0.1 | 27220501 |
| ECLASS 9.0 | 27220501 |
| ECLASS 8.0 | 27220501 |
| ECLASS 5.1 | 27220501 |
| ETIM 9.0 | EC002714 |
| ETIM 8.0 | EC002714 |
| ETIM 7.0 | EC002714 |
| ETIM 6.0 | EC002714 |
| ETIM 5.0 | EC002714 |
| UNSPSC 12.1 | 39121550 |