Datasheet excerpt: Technical data of GA18/GK18/25/115/161
| Item Specification |
|---|
| Through-beam sensor with M18 threaded design, plastic enclosure, front optical surface, 20 m detection range, red light, light on functionality, AC/DC version, NPN-FET output, and permanent cable |
Classifications
| System elements | ||
|---|---|---|
| Emitter | GA18/115 | |
| Receiver | GK18/25/115/161 | |
| Overall specifications | ||
| Operational sensing range | 0 ... 20 m | |
| detection range threshold | 25 m | |
| illumination source | LED | |
| Illumination type | modulated red light in the visible spectrum , 640 nm | |
| Size of the illumination spot | approx. 1000 mm at 25 m | |
| angle of opening | approx. 3 ° | |
| optical surface | frontal | |
| Ambient light threshold | 30000 Lux | |
| Included accessories | mounting aids | |
| Indicators/operation controls | ||
| Operational status indicator | Green LED, continuously illuminated Power on | |
| operation indicator | Transducer: yellow LED, illuminates when the light beam is unobstructed, blinks when the functioning reserve is low; OFF when the light beam is blocked | |
| Electrical parameters | ||
| Operational voltage | 20 ... 250 V AC/DC | |
| No-load input current | < 2.5 mA for each device | |
| Output | ||
| Type of switch | light-on | |
| Output signal | N-channel MOSFET with short circuit protection | |
| Switching voltage level | max. 250 V AC/DC | |
| Switching capacity | max. 200 mA | |
| voltage loss | = 3.5 V AC/DC | |
| commutation frequency | 50 Hz | |
| reaction time | = 10 ms | |
| Compliance | ||
| Product specification | EN 60947-5-2 | |
| Adherence to standards and directives | ||
| Compliance with standards | ||
| Standards | UL 508 | |
| Certifications and approvals | ||
| Ingress protection rating | II, rated insulation voltage = 250 V AC with pollution degree 1-2 according to IEC 60664-1 | |
| UL certification | cULus Certified, Type 1 housing For overcurrent protection, connect a fuse with a maximum rated current of 3 A 250 V AC/DC |
|
| CCC certification | Approved by China Compulsory Certification (CCC) | |
| Environmental conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Ambient storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical characteristics | ||
| Protection等级 | IP67 | |
| Linkage | 2 m permanently attached cable | |
| Material | ||
| Housing | ABS / PBT | |
| optical surface | PMMA | |
| Mass | approx. 80 g for each unit | |
| Measurements | ||
| Length | 56 mm | |
| Diameter | 18 mm | |
Download Specification for GA18/GK18/25/115/161