Photoelectric Sensor Pepperl+Fuchs LGS17
Pepperl+Fuchs Categories
Datasheet excerpt: Technical data of LGS17
| Item Specification |
|---|
| Automation safety light curtain featuring a beam spacing of 17 mm, equipped with an IO-Link interface, push-pull output, and a permanent cable with M12 connector |
Classifications
| Overall specifications | ||
|---|---|---|
| Operational sensing range | Standard : 0.3 ... 6 m Option /35: 0.5 ... 8 m |
|
| detection range threshold | Standard : 7.5 m Option /35: 10 m |
|
| illumination source | IRED | |
| Illumination type | modulated infrared light at 850 nm | |
| field elevation | see Table 1, max. 3200 mm | |
| Beam intersection | Factory configuration: three beam crossing, can be disabled | |
| Beam suppression | adjustable max. 2 fixed suppressible light beams (blanking) | |
| Beam separation | 16.67 mm | |
| Beam count | see Table 1, max. 193 | |
| Operation mode | Emitter: Emitter power configurable in two settings | |
| imaging resolution | without beam overlap: 17 mm with beam overlap: 8.5 mm within 25% and 75% of the range |
|
| angle of opening | 10 ° | |
| Ambient light threshold | > 50000 Lux (when the external light source is positioned outside the opening angle) | |
| Parameters related to functional safety | ||
| MTTFd | 25 a | |
| task duration (TM) | 20 a | |
| Diagnostic Range (DC) | 60 % | |
| Indicators/operation controls | ||
| Operational status indicator | Power on: green LED, continuously illuminated, undervoltage indicator: green LED, pulsating (approx. 0.8 Hz), short-circuit: green LED flashing (approx. 4 Hz) | |
| operation indicator | Emitter: Yellow LED, activates at high emission intensity, turns off at low emission intensity Transducer: Yellow LED: lights up when an object is detected and flashes when nearing the operational limit (4 Hz) Error notification: Yellow LED blinks (8 Hz) in both emitter and receiver |
|
| control components | Transducer: 2 tactile buttons for configuration | |
| Parameterization signal | IO-Link communication: green LED turns off momentarily (1 Hz) | |
| Electrical parameters | ||
| Operational voltage | 18 ... 30 V DC | |
| Ripple | 10 % | |
| No-load input current | Emitter =: 50 mA Transducer: = 150 mA (in idle state without outputs) |
|
| Delay time prior to availability | see Table 1, max. 3 s | |
| Connection point | ||
| Type of interface | IO-Link | |
| Protocol | IO-Link V1.0 | |
| Mode | COM2 (38.4 kBit/s) | |
| Input | ||
| Verification input | Deactivation of emitter with +UB or 0 V at pin 4 (transmitter) | |
| Input function | Range input activation begins at 1.6 m (or 2 m for option /35) with +UB or 0 V applied to pin 2 (transmitter) Teach-In interface for configuration on pin 8 (receiver) |
|
| Output | ||
| Stability fault indication output | Stability Control (SC) 1 PNP, featuring short-circuit protection and reverse polarity protection on pin 2 (receiver) | |
| Type of switch | Factory setting: dark mode enabled, switchable to light mode | |
| Output signal | Switching output (detection field C/Q) 1 push-pull (4 in 1) output, short-circuit safeguarded, reverse polarity safeguarded on pin 4 (receiver) Height monitoring (H1, H2. H3) 3 push-pull (4 in 1) outputs, short-circuit protected, reverse polarity safeguarded on pin 5, pin 6, pin 7 (receiver) |
|
| activation threshold | Factory setting: The signal tracking for the threshold value is turned off, enhancing the optical resolution by up to 4 mm; can be switched to enable active signal tracking | |
| Switching voltage level | max. 30 V DC | |
| Switching capacity | max. 100 mA | |
| voltage loss | = 2 V DC | |
| commutation frequency | see Table 1, max. 129 Hz | |
| reaction time | see Table 1, max. 16 ms | |
| Timing feature | Post-delay adjustable from 0 ... 1.25 s in 5 ms increments (configuration through IO-Link only) | |
| Compliance | ||
| Communication interface | IEC 61131-9 | |
| Product specification | EN 60947-5-2 | |
| Certifications and approvals | ||
| Ingress protection rating | III ( IEC 61140 ) | |
| UL certification | cULus Certified | |
| CCC certification | CCC certification / marking not necessary for products rated ≤36 V | |
| Environmental conditions | ||
| Ambient temperature | Standard : -10 ... 60 °C (14 ... 140 °F) Option /146: -30 ... 60 °C (-22 ... 140 °F) |
|
| Ambient storage temperature | -30 ... 70 °C (-22 ... 158 °F) | |
| Mechanical characteristics | ||
| Conductor cross-sectional area | min. 0.25 mm2 | |
| Housing length L | see Table 1, max. 3360 mm | |
| Protection等级 | IP67 | |
| Linkage | Emitter: connection cable featuring 4-pin, M12 x 1 connector, 330 mm overall length Transducer: connecting cable with 8-pin, M12 x 1 connector , 350 mm total length |
|
| Material | ||
| Housing | extruded aluminum profile, silver anodized | |
| optical surface | synthetic panell, polycarbonate | |
| Mass | see Table 1, max. 1750 g (per profile) | |
| Measurements | ||
| Width | 20 mm | |
| Depth | 30.5 mm | |
| Cable duration | max. 30 m | |
Download Specification for LGS17
Download PDFRELATED PRODUCTS