Photoelectric Sensor Pepperl+Fuchs MLV12-54/32/82b/124
Pepperl+Fuchs Categories
Photoelectric Sensor MLV12-54/32/82b/124
Brand: Pepperl+Fuchs
Product Code:
Datasheet excerpt: Technical data of MLV12-54/32/82b/124
| Item Specification |
|---|
| Durable retroreflective sensor tailored for complex applications, featuring a compact design, polarization filter, 9 m detection range, utilizing red light, light/dark ON mode, PNP output, stability alarm output, and M12 connector |
Classifications
| Overall specifications | ||
|---|---|---|
| Operational sensing range | 0 ... 6.5 m | |
| reflector spacing | 0.01 ... 6.5 m | |
| detection range threshold | 9 m |
|
| Reference point | H85-2 reflective surface | |
| illumination source | LED | |
| Illumination type | modulated red light in the visible spectrum , 660 nm | |
| polarizing filter | yes | |
| Size of the illumination spot | approx. 170 mm at detection range 6.5 m | |
| angle of opening | 1.5 ° | |
| Ambient light threshold | ||
| constant illumination | 50000 Lux | |
| Modulated illumination | 5000 Lux | |
| Parameters related to functional safety | ||
| MTTFd | 1000 a | |
| task duration (TM) | 20 a | |
| Diagnostic Range (DC) | 0 % | |
| Indicators/operation controls | ||
| Operational status indicator | Green LED, blinks in the event of a short circuit | |
| operation indicator | 2 yellow LEDs illuminate when the light beam is unobstructed, flash when the functioning reserve is insufficient, and turn off when the light beam is broken | |
| control components | Rotary switch for light/dark settings, Sensitivity calibration control | |
| Electrical parameters | ||
| Operational voltage | 10 ... 30 V DC | |
| Ripple | max. 10 % | |
| No-load input current | max. 40 mA | |
| Output | ||
| Stability fault indication output | 1 PNP, disabled when the level drops below the functioning reserve after approximately 5 s Automatically disabled if the beam is broken 4 times during the flash duration |
|
| Type of switch | switchable light/dark mode | |
| Output signal | 1 PNP output, safeguarded against short circuits, protected against reverse polarity, open collector | |
| Switching voltage level | max. 30 V DC | |
| Switching capacity | max. 0.2 A | |
| voltage loss | = 2.5 V DC | |
| commutation frequency | 1000 Hz | |
| reaction time | 0.5 ms | |
| Compliance | ||
| Product specification | EN 60947-5-2 | |
| Adherence to standards and directives | ||
| Compliance with standards | ||
| Resistance to shock and impact | IEC / EN 60068. half-sine, 40 g in each X, Y, and Z axes | |
| vibration durability | IEC / EN 60068-2-6. Sinusoidal. 10 - 150 Hz, 5 g in each of the X, Y, and Z axes | |
| Certifications and approvals | ||
| Ingress protection rating | II, rated voltage = 300 V AC with pollution degree 1-2 according to IEC 60664-1 | |
| UL certification | cULus | |
| CCC certification | CCC certification / marking not necessary for products rated ≤36 V | |
| Environmental conditions | ||
| Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) | |
| Ambient storage temperature | -40 ... 75 °C (-40 ... 167 °F) | |
| Mechanical characteristics | ||
| Protection等级 | IP67 | |
| Linkage | Metal connector, M12, 5-pin, rotatable at 90° | |
| Material | ||
| Housing | Frame: nickel-plated, die-cast zinc, Lateral components: fiberglass-reinforced plastic PC |
|
| optical surface | synthetic panel | |
| Mass | 60 g | |
| Measurements | ||
| Height | 49 mm | |
| Width | 41.5 mm | |
| Depth | 15 mm | |
Download Specification for MLV12-54/32/82b/124