Datasheet excerpt: Technical data of OBT80-R2-E0-P-L
| Item Specification |
|---|
| Laser triangulation method sensor featuring background suppression, ultra-compact form factor with M2 mounting, 80 mm sensing range, light on capability, NPN output, 2 m permanently attached cable |
Classifications
| Overall specifications | ||
|---|---|---|
| Detection distance | 20 ... 80 mm | |
| Reference point | standard black, 100 mm x 100 mm | |
| illumination source | laser diode | |
| Illumination type | modulated red light in the visible spectrum , 680 nm | |
| Laser specified ratings | ||
| Note | LASER LIGHT , DO NOT STARE INTO BEAM | |
| Laser category | 1 | |
| Wavelength | 680 nm | |
| Beam spreading | > 5 mrad | |
| pulse duration | approx. 3 µs | |
| Repetition frequency | approx. 16.6 kHz | |
| maximum pulse energy | 9.5 nJ | |
| Black-white contrast (6 %/90 %) | < 15 % at 80 mm | |
| Size of the illumination spot | approximately 2 mm at a separation of 80 mm | |
| angle of opening | approx. 2 ° | |
| optical surface | frontal | |
| Ambient light threshold | EN 60947-5-2 : 30000 Lux | |
| Parameters related to functional safety | ||
| MTTFd | 800 a | |
| task duration (TM) | 20 a | |
| Diagnostic Range (DC) | 0 % | |
| Indicators/operation controls | ||
| Operational status indicator | LED green, continuously illuminated Power on, short-circuit: LED green blinking (approximately 4 Hz) | |
| operation indicator | Yellow indicator LED: activates when an object is sensed | |
| Electrical parameters | ||
| Operational voltage | 12 ... 24 V | |
| No-load input current | < 10 mA | |
| Ingress protection rating | III | |
| Output | ||
| Type of switch | Non-contact / light activated | |
| Output signal | 1 NPN output, protected against short circuits, safeguarded against reverse polarity, open collector | |
| Switching voltage level | max. 30 V DC | |
| Switching capacity | max. 50 mA, resistive load | |
| voltage loss | = 1.5 V DC | |
| commutation frequency | approx. 2 kHz | |
| reaction time | 250 µs | |
| Compliance | ||
| Product specification | EN 60947-5-2 | |
| Laser safety | EN 60825-1:2007 | |
| Certifications and approvals | ||
| UL certification | E87056, cULus Recognized, Class 2 Power Supply | |
| CCC certification | CCC certification / marking not necessary for products rated ≤36 V | |
| FDA certification | IEC 60825-1:2007 conforms with 21 CFR 1040.10 and 1040.11, excluding deviations as stated in Laser Notice No. 50, dated June 24, 2007 | |
| Environmental conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Ambient storage temperature | -30 ... 70 °C (-22 ... 158 °F) | |
| Mechanical characteristics | ||
| Protection等级 | IP67 | |
| Linkage | 2 m permanently attached cable | |
| Material | ||
| Housing | PC/ABS and thermoplastic polyurethane | |
| optical surface | PC | |
| Cable | PUR | |
| mounting | mounting screws, 2 x M2 hex socket screws included in the package | |
| Mass | approx. 20 g | |
| Measurements | ||
| Height | 24 mm | |
| Width | 7.5 mm | |
| Depth | 11.2 mm | |
| Cable duration | 2 m | |