Photoelectric Sensor Pepperl+Fuchs RLG28-55-7462
Pepperl+Fuchs Categories
Datasheet excerpt: Technical data of RLG28-55-7462
| Item Specification |
|---|
| Retroreflective area sensor featuring 6 beams in a commonly utilized standard photoelectric enclosure, red light, 4 m detection range, switchable light/dark mode, push-pull output, M12 plug |
Classifications
| Overall specifications | ||
|---|---|---|
| Operational sensing range | 0 ... 4 m | |
| reflector spacing | Reflector A80: 0.4 ... 4 m, H85-2 reflective surface: 0.2 ... 4 m, foil reflector OFR-100/100: 0.4 ... 3 m | |
| detection range threshold | 5.6 m | |
| detection range | typical 60 mm , Object has to cover the refelector completely in one dimension | |
| Reference point | Reflector A80 H85-2 foil reflector OFR-100/100 | |
| illumination source | LED | |
| Illumination type | modulated red light in the visible spectrum , 625 nm | |
| polarizing filter | yes | |
| Beam count | 6 | |
| Size of the illumination spot | approximately 220 mm at a detection range of 4 m | |
| angle of opening | +/- 2.5 ° | |
| Ambient light threshold | 5000 Lux | |
| Accuracy | 12 mm | |
| recalibration | Receiver realignment activated after > 30 seconds | |
| Parameters related to functional safety | ||
| MTTFd | 310 a | |
| task duration (TM) | 20 a | |
| Diagnostic Range (DC) | 0 % | |
| Indicators/operation controls | ||
| Operational status indicator | Green LED, continuously illuminated Power on Undervoltage indicator: Green LED, flashing (approximately 0.8 Hz) short-circuit: LED green blinking (approximately 4 Hz) |
|
| operation indicator | 2 yellow LEDs illuminate when the light beam is unobstructed, flash when the functioning reserve is insufficient, and turn off when the light beam is broken Teach-In: Yellow indicator LED/green; equi-phase flashing; 2.5 Hz |
|
| control components | rotary switch for light/dark adjustment , learning key | |
| Electrical parameters | ||
| Operational voltage | 12 ... 30 V DC |
|
| Ripple | max. 10 % | |
| No-load input current | max. 50 mA | |
| Output | ||
| Stability fault indication output | 1 Push-pull signaling output, enabled when there is adequate functioning reserve, disabled when there is insufficient functioning reserve, alternates for a minimum of 10 s when the signal quality is low (to verify alignment and facilitate teach-in) | |
| Type of switch | switchable light/dark on | |
| Output signal | 1 push-pull (4 in 1) output, protected against short circuits, reverse polarity protection included | |
| Switching voltage level | max. 30 V DC | |
| Switching capacity | max. 100 mA | |
| voltage loss | = 2.5 V DC | |
| commutation frequency | 230 Hz | |
| reaction time | 1 ms | |
| Compliance | ||
| Product specification | EN 60947-5-2 | |
| Certifications and approvals | ||
| UL certification | E87056, cULus Certified, Class 2 power supply, type rating 1 | |
| CCC certification | CCC certification / marking not necessary for products rated ≤36 V | |
| Environmental conditions | ||
| Ambient temperature | -10 ... 40 °C (14 ... 104 °F) |
|
| Ambient storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical characteristics | ||
| Protection等级 | IP67 | |
| Linkage | 4-pin, M12 x 1 connector | |
| Material | ||
| Housing | Plastic ABS | |
| optical surface | synthetic panel | |
| Mass | 100 g | |
| Measurements | ||
| Height | 88 mm | |
| Width | 25.8 mm | |
| Depth | 54.3 mm | |
Download Specification for RLG28-55-7462
Download PDFRELATED PRODUCTS