Photoelectric Sensor Pepperl+Fuchs RLK28-55/31/116
Pepperl+Fuchs Categories
Datasheet excerpt: Technical data of RLK28-55/31/116
| Item Specification |
|---|
| Retroreflective detector featuring a polarization filter |
Classifications
| Overall specifications | ||
|---|---|---|
| Operational sensing range | 0 ... 17 m | |
| reflector spacing | 0.05 ... 17 m | |
| detection range threshold | 21 m |
|
| Reference point | H85-2 reflective surface | |
| illumination source | LED | |
| Illumination type | modulated red light in the visible spectrum | |
| polarizing filter | yes | |
| Size of the illumination spot | approximately 290 mm at a distance of 17 m | |
| angle of opening | emitter 1.2° receiver 2nd |
|
| Ambient light threshold | 80000 Lux | |
| Parameters related to functional safety | ||
| MTTFd | 600 a | |
| task duration (TM) | 20 a | |
| Diagnostic Range (DC) | 0 % | |
| Indicators/operation controls | ||
| Operational status indicator | LED green | |
| operation indicator | 2 yellow LEDs illuminate when the light beam is unobstructed, flash when the functioning reserve is insufficient, and turn off when the light beam is broken | |
| control components | Sensitivity calibration (Calibration to < 25% of the usable functioning range), Light-on/dark-on toggle switch | |
| Electrical parameters | ||
| Operational voltage | 12 ... 240 V AC/DC | |
| Energy usage | = 3.5 VA | |
| Output | ||
| Type of switch | switchable light/dark mode | |
| Output signal | Relay, 1 alternator | |
| Switching voltage level | max. 250 V AC/DC | |
| Switching capacity | max. 2 A | |
| Conversion power | DC: max. 50 W AC: max. 500 VA | |
| commutation frequency | 25 Hz | |
| reaction time | 20 ms | |
| Compliance | ||
| Product specification | EN 60947-5-2 | |
| Certifications and approvals | ||
| Ingress protection rating | II, rated insulation voltage = 250 V AC with pollution degree 1-2 according to IEC 60664-1 Output circuit insulated from control circuit in accordance with IEC 61140. Caution! The protection class 2 applies only when the terminal chamber is secured |
|
| UL certification | E87056, cULus Certified Caution: This equipment is categorized as open-type. It should be installed within an enclosure that is properly designed to protect against internal fires and personal injury due to access to live components in accordance with UL 508 |
|
| CCC certification | Approved by China Compulsory Certification (CCC) | |
| Environmental conditions | ||
| Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) | |
| Ambient storage temperature | -40 ... 60 °C (-40 ... 140 °F) | |
| Mechanical characteristics | ||
| Protection等级 | IP67 | |
| Linkage | terminal chamber featuring 8 spring-loaded terminals for wire cross-section of 0.5 ... 1.5 mm2 , Insulation stripping 7.5 ... 8.5 mm , M16 x 1.5 cable gland | |
| Material | ||
| Housing | Plastic ABS | |
| optical surface | synthetic panel | |
| Mass | 112 g | |
| Measurements | ||
| Height | 88 mm | |
| Width | 25.8 mm | |
| Depth | 65.5 mm | |
Download Specification for RLK28-55/31/116