Datasheet excerpt: Technical data of RLK29-55/59/116-Set
| Item Specification |
|---|
| Robust, compact, long range photoelectric sensors for detecting people, objects and vehicles |
Classifications
| Overall specifications | ||
|---|---|---|
| Operational sensing range | 0 ... 12 m | |
| reflector spacing | 0.04 ... 12 m | |
| detection range threshold | 14 m | |
| Reference point | reflector C110-2 | |
| illumination source | LED | |
| Illumination type | modulated red light in the visible spectrum , 640 nm | |
| Size of the illumination spot | approximately 35 mm at a separation of 12 m | |
| angle of opening | ± 1 ° | |
| Ambient light threshold | 90000 Lux | |
| Included accessories | reflector C110-2, mounting bracket with installation materials | |
| Parameters related to functional safety | ||
| MTTFd | 1460 a | |
| task duration (TM) | 20 a | |
| Diagnostic Range (DC) | 0 % | |
| Indicators/operation controls | ||
| operation indicator | LED red illuminates: when beam path is unobstructed flashes: when the level drops below the operational reserve off: when the beam is blocked |
|
| Electrical parameters | ||
| Operational voltage | 24 ... 230 V AC/DC | |
| Ripple | 10 % | |
| No-load input current | = 8.5 mA | |
| Energy usage | 0.2 W at 24 V DC , 1.8 W at 230 V AC 3 VA | |
| Output | ||
| Type of switch | dark-on | |
| Output signal | Relay, 1 alternator | |
| Switching voltage level | 230 V AC | |
| Switching capacity | max. 2 A | |
| commutation frequency | 7 Hz | |
| reaction time | 50 ms | |
| Compliance | ||
| Product specification | EN 60947-5-2 | |
| Certifications and approvals | ||
| CE compliance | yes | |
| EAC compliance | TR CU 020/2011 TR CU 004/2011 |
|
| UL certification | cULus Certified Caution: This equipment is classified as open-type. It must be installed within an enclosure that is appropriately designed to safeguard against internal fires and personal injury due to access to live components in accordance with UL 508 |
|
| CCC certification | Approved by China Compulsory Certification (CCC) | |
| Environmental conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Ambient storage temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Mechanical characteristics | ||
| Protection等级 | IP67 | |
| Linkage | terminal chamber | |
| Material | ||
| Housing | Plastic ABS, flame-retardant | |
| optical surface | synthetic panel | |
| Mass | 100.7 g | |
| Measurements | ||
| Height | 88 mm | |
| Width | 25.8 mm | |
| Depth | 65.5 mm | |
| Note | Safety fuse = 2 A (time-delay) in accordance with IEC 60127-2 Sheet 1 Recommendation: after a short circuit, verify that the device is functioning properly |
|