Datasheet excerpt: Technical data of VDM18-100/20/88/122/151
| Item Specification |
|---|
| Universal distance sensor for object measurement, 100 mm detection range, red laser light, laser class 2, RS485 communication interface, 2 x PNP outputs, analog output, and M12 plug |
Classifications
| Overall specifications | ||
|---|---|---|
| Measurement range | 30 ... 100 mm | |
| illumination source | laser diode typ. service life 50,000 h at Ta = +40 °C |
|
| Illumination type | modulated red light in the visible spectrum | |
| Laser specified ratings | ||
| Note | LASER LIGHT , DO NOT STARE INTO BEAM | |
| Laser category | 2 | |
| Wavelength | 650 nm | |
| Illumination point depiction | approximately 1.5 mm x 3 mm at 100 mm | |
| Measurement technique | Laser triangulation method | |
| Ambient light threshold | = 5000 Lux | |
| Rated specifications | ||
| Non-linearity error | 0.25 % of the measuring range | |
| Repeatability accuracy | < 0.25 % of the measured value | |
| Accuracy | < 0.1 % of the measuring range | |
| Temperature variation | < 0.02 % / °C | |
| Indicators/operation controls | ||
| Operational status indicator | LED green | |
| operation indicator | 2 yellow LEDs: Output switching status (each output), 4 green LEDs: Operational mode | |
| control components | Control panel: Adjuster for set point, functioning mode, analog output (S - Set, T - Toggle) | |
| Parameterization signal | LED red | |
| Electrical parameters | ||
| Operational voltage | 18 ... 30 V DC | |
| No-load input current | = 40 mA at 24 V DC | |
| Ingress protection rating | II, nominal voltage = 50 V DC | |
| Delay time prior to availability | = 300 ms | |
| Connection point | ||
| Type of interface | RS-485 | |
| Output | ||
| Connections | RS-485 | |
| Output signal | 2 independent PNP outputs, protected against short circuits and reverse polarity | |
| Switching capacity | max. 100 mA | |
| Output measurement | 1 analog output 4 ... 20 mA, protected against short-circuit and overload, Rmax = 500 Ohm | |
| commutation frequency | = 1 kHz | |
| reaction time | 0.4 ms | |
| Adherence to standards and directives | ||
| Compliance with directives | ||
| EMC Regulation 2004/108/EC | EN 60947-5-2 | |
| Compliance with standards | ||
| Laser category | DIN EN 60825-1:2008, IEC 60825-1:2007 | |
| Certifications and approvals | ||
| UL certification | cULus Certified | |
| Certifications | CE, cULus | |
| Environmental conditions | ||
| Ambient temperature | -10 ... 60 °C (14 ... 140 °F) | |
| Ambient storage temperature | -20 ... 80 °C (-4 ... 176 °F) | |
| Mechanical characteristics | ||
| Protection等级 | IP67 | |
| Linkage | M12 connector, 8-pole | |
| Material | ||
| Housing | ABS, shock-resistant | |
| optical surface | PMMA | |
| Mass | approx. 43 g | |
| Measurements | ||
| Height | 50 mm | |
| Width | 17 mm | |
| Depth | 50 mm | |
Download Specification for VDM18-100/20/88/122/151