- Simplified adjustment of the sensing range using a variable resistor
- With AC/ DC combined output
- Two-conductor technology
- Excellent noise resistance
- Programmable output function typically open / default closed
Product characteristics
| Output feature | typically open / closed; (selectable) |
| Detection range[mm] | 15 |
| Housing | Screw-type |
| measurements[mm] | M30 x 1.5 / L = 125 |
| Voltage for operation[V] | 20...250 AC/DC |
| Safety feature rating | II |
| Reverse polarity safeguard | no |
| Weight[g] | 137 |
| Housing | Screw-type |
| Installation | non-recessed mountable |
| measurements[mm] | M30 x 1.5 / L = 125 |
| Thread specification | M30 x 1.5 |
| Substance | PBT; end cap: PC |
Displays / operating elements
| Display |
| ||
| Necessary safeguarding | miniature fuse compliant with IEC60127-2 sheet 1; = 2 A; quick acting | ||
| Surrounding temperature value[°C] | -25...70 | ||
| Safety feature | IP 65 | ||
| Enhanced immunity | yes; (Enhanced immunity to conducted radio frequency interference) |
Monitoring range
| Detection range[mm] | 15 | |
| Adjustable sensing range | yes | |
| sensing range set at the factory[mm] | 15 | |
| Actual sensing range Sr[mm] | 15 ± 10 % | |
| Operational range[mm] | 0...12.1 | |
| Output feature | typically open / closed; (selectable) | |
| Max. voltage drop at switching output DC[V] | 8 | |
| Max. voltage drop at switching output AC[V] | 10 | |
| Minimum load current[mA] | 5 | |
| Max. stray current[mA] | 2.5 (250 V AC) / 1.7 (110 V AC) / 1.5 (24 V DC) | |
| Continuous current rating of the switching output AC[mA] | 200; (for UL application: 250 / 100 DC) | |
| Continuous current rating of the switching output DC[mA] | 200; (for UL application: 250 AC / 100 DC) | |
| Momentary current capacity of switching output[mA] | 1500; (20 ms / 0,5 Hz) | |
| AC switching frequency[Hz] | 25 | |
| DC switching frequency[Hz] | 40 | |
| Short-circuit resistant | no | |
| Overcurrent protection | no | |
| Adjustment coefficient | glass: 0.4 / water: 1 / ceramics: 0.2 / PVC: 0.2 | |
| Hysteresis[% of Sr] | 1...15 | |
| Setting-point drift[% of Sr] | -15...15 | |