Flow Sensor Ifm SBG233
IFM CATEGORIES
Flow Sensor SBG233
Brand: Ifm
Product Code: SBG12IF0FRKG
- Accurate detection of flow and medium temperature value
- Compatible with water, coolants, oil, and glycol solutions due to built-in measurement graphs
- Very fast (~10 ms) response time
- Featuring switching output, analog output, or frequency output along with IO-Link
- Easily readable LED display featuring a red/green color transition
Product characteristics
| Total count of inputs and outputs | Count of digital outputs: 2; Count of analog outputs: 1 | ||
| Measuring span |
| ||
| Connection for process | screw connection G 1/2 with internal threading | ||
| System | gold-plated terminals | ||
| Application | for commercial applications | ||
| Media | Fluids; water; glycol mixtures; coolants | ||
| Comment on medium |
| ||
| Intermediate temperature value[°C] | -10...100 | ||
| Minimum force per unit area before bursting[bar] | 160 | ||
| Pressure classification |
| ||
| MAWP (for uses in compliance with CRN)[bar] | 40 | ||
| Response duration[s] | 0.01 | ||
| Damping process parameter dAP[s] | 0...5 | ||
| Damping for the analog output dAA[s] | 0...5 |
Software / programming
| Configuration options | hysteresis / range; typically open / default closed; switching configuration; current/frequency output; medium choice; damping for the switching output / analog output; display can be rotated and deactivated; norm measurement unit; measured value color | ||||
| communication interface | IO-Link | ||||
| Mode of transmission | COM2 (38,4 kBaud) | ||||
| IO-Link version | 1.1 | ||||
| SDCI specification | IEC 61131-9 CDV | ||||
| Configurations | Intelligent Sensor: Data Process Variable; Device Identification | ||||
| SIO mode | yes | ||||
| Necessary master port category | A | ||||
| Analog data process | 2 | ||||
| Data binary process | 2 | ||||
| Minimum process cycle duration[ms] | 5 | ||||
| Supported DeviceIDs |
| ||||
| Measuring span |
| ||||
| Show range |
| ||||
| Definition of detail level |
| ||||
| Setpoint SP |
| ||||
| Reset threshold rP |
| ||||
| Frequency termination point, FEP |
| ||||
| In increments of |
| ||||
| Frequency at termination point FRP[Hz] | 10...10000 | ||||
| Measurement dynamics | 1:50 |
Inputs / outputs
| Total count of inputs and outputs | Count of digital outputs: 2; Count of analog outputs: 1 | ||
| Voltage for operation[V] | 18...30 DC; (to SELV/PELV) | ||
| Current draw[mA] | < 50 | ||
| Safety feature rating | III | ||
| Reverse polarity safeguard | yes | ||
| Activation delay time[s] | < 3 | ||
| Overall count of outputs | 2 | ||
| Output response | output signal; analog output; frequency output; IO-Link; (customizable) | ||
| Count of digital outputs | 2 | ||
| Output feature | typically open / closed; (customizable) | ||
| Max. voltage drop at switching output DC[V] | 2 | ||
| Continuous current rating of the switching output DC[mA] | 150; (per output 2 x 200 (...60 °C); 2 x 250 (...40 °C)) | ||
| Mechanical switching cycles | 10 million | ||
| Total analog outputs | 1 | ||
| Analog current output[mA] | 4...20 | ||
| Max. capacity[O] | 500 | ||
| Overcurrent protection | yes | ||
| Overcurrent protection | yes | ||
| Output frequency[Hz] | 0...10000 | ||
| Precision (within the measurement range) | ± (4 % MW + 1 % MEW); (Q > 0,5 l/min; medium and operating temperature value: +22 °C ± 4K) | ||
| Reproducibility | ± 1 % MEW | ||
| Surrounding temperature value[°C] | 0...60 | ||
| Comment on operating temperature value range |
| ||
| Temperature for storage[°C] | -15...80 | ||
| Safety feature | IP 65; IP 67 |
Download Specification for SBG233
Download PDFRELATED PRODUCTS