Product Code: SUR54HGB50KG/W/US-100-IPF

  • Consistent monitoring of flow and medium temperature value
  • Compatible with water, oils, and glycol-based solutions
  • Designed for installation within pipes
  • Equipped with two expandable analog outputs
  • Easily readable numerical display

Share on:

Product characteristics

Total count of inputs and outputs Quantity of analog outputs: 2
Measuring span
0...200 l/min0...52.84 gpm
Connection for process screw connection G 1 1/4 with outdoor thread and flat sealing feature
System gold-plated terminals
Application for commercial applications
Setup connection to pipe via an adapter
Media water; glycol mixtures; coolants; oils
Comment on medium
lightweight oils with viscosity: 7...40 mm²/s (40 °C)
high-viscosity oils with viscosity: 30…68 mm²/s (40 °C)
Intermediate temperature value[°C] -10...80
Pressure classification
16 bar1.6 MPa
Response duration[s] 0.25; (dAP = 0)
Damping process parameter dAP[s] 0...1
Display
Indicator unit6 x LED, green (l/min, m³/h, gpm, gph, °C, °F)
Obtained valuesalphanumeric display, 4-digit readout
Configurationalphanumeric display, 4-digit readout
Indicator unit l/min; m³/h; gpm; gph; °C; °F

Operating conditions

Surrounding temperature value[°C] -10...60
Temperature for storage[°C] -25...80
Safety feature IP 67
Measuring span
0...200 l/min0...52.84 gpm
Show range
0...240 l/min0...63.42 gpm
Definition of detail level
0.1 l/min0.02 gpm
Analog initiation point ASP
0...160 l/min0...42.28 gpm
Analog endpoint AEP
40...200 l/min10.28...52.84 gpm
Max. maximum flow rate[l/min] 220
In increments of
0.1 l/min0.02 gpm

Inputs / outputs

Total count of inputs and outputs Quantity of analog outputs: 2
Voltage for operation[V] 19...30 DC; (to SELV/PELV)
Current draw[mA] 100
Minimum insulation resistance[MO] 100; (500 V DC)
Safety feature rating III
Reverse polarity safeguard yes
Activation delay time[s] 10
Measuring method ultrasonics
Overall count of outputs 2
Output response analog signal
Total analog outputs 2
Analog current output[mA] 4...20; (expandable)
Max. capacity[O] 500
Overcurrent protection yes
Method of overcurrent protection yes (momentary)
Overcurrent protection yes
Precision (within the measurement range) water: < ± (3 % MW + 0.2 % MEW); glycol (35 %), oil (viscosity 68 mm²/s at 40 °C): < ± (8 % MW + 0.5 % MEW)
Reproducibility 1 l/min; 60 l/h; 0,05 gpm; 3 gph
Weight[g] 1883
Housing rectangular shape
measurements[mm] 130 x 100 x 80.5
Substance enclosure: anodized AlMgSi0.5; sealing: FKM; PA 6.6; protective film: PA
Substances (contacted components) stainless steel (1.4404 / 316L); FKM; PPS; Centellen 200
Connection for process screw connection G 1 1/4 with outdoor thread and flat sealing feature

Download Specification for SU9004