Flow Sensor Ifm SM4120


IFM CATEGORIES

Flow Sensor Ifm sm4120

Flow Sensor SM4120

Brand: Ifm
Product Code: SMR14XGXFRKG/US-100

  • Accurate monitoring of flow, consumption, and medium temperature value
  • Excellent precision, reproducibility, and measurement responsiveness
  • Featuring switching output, analog output, and pulse output
  • Easily readable color display featuring a red/green color transition
  • No lengths for inlet and outlet pipes are necessary

Share on:

Product characteristics

Total count of inputs and outputs Count of digital outputs: 2; Count of analog outputs: 1
Measuring span[ml/min] 5...5000
Connection for process screw connection G 1/4 with outdoor thread and DN6 flat sealing element
System gold-plated terminals
Media Conductive fluids; water; aqueous media
Comment on medium
conductivity: = 20 µS/cm
viscosity: < 70 mm²/s (40 °C)
Intermediate temperature value[°C] -20...90
Pressure classification
16 bar1.6 MPa
Precision (within the measurement range) ± (0,8 % MW + 0,2 % MEW)
Reproducibility ± 0,2 % MEW
Surrounding temperature value[°C] -20...60
Temperature for storage[°C] -25...80
Safety feature IP 65; IP 67

Reaction times

Initialization delay[s] 0...50
Response duration[s] < 0.25; (dAP = 0, T09)
Damping process parameter dAP[s] 0...5
Configuration options hysteresis / band; typically open / default closed; switching method; frequency output; current/pulse output; startup delay; display can be turned off; display module
Overall count of outputs 2
Output response output signal; analog output; pulse signal; IO-Link; frequency signal; (customizable)
Electrical engineering design PNP/NPN
Count of digital outputs 2
Output feature typically open / closed; (customizable)
Max. voltage drop at switching output DC[V] 2
Continuous current rating of the switching output DC[mA] 100
Total analog outputs 1
Analog current output[mA] 4...20; (expandable)
Max. capacity[O] 500
Pulse output signal flow measurement device
Overcurrent protection yes
Method of overcurrent protection yes (momentary)
Overcurrent protection yes

Inputs / outputs

Total count of inputs and outputs Count of digital outputs: 2; Count of analog outputs: 1
Voltage for operation[V] 18...30 DC; (to SELV/PELV)
Current draw[mA] < 80
Safety feature rating III
Reverse polarity safeguard yes
Activation delay time[s] 5
Measuring method magnetic-induction
Inputs reset function
Measuring span[ml/min] 5...5000
Indicate range[ml/min] -6000...6000
Definition of detail level[ml/min] 1
Setpoint SP[ml/min] 33...5000
Reset threshold rP[ml/min] 7...4974
Analog initiation point ASP[ml/min] 0...3993
Analog endpoint AEP[ml/min] 1007...5000
Minimal flow termination LFC[ml/min] 5...250
Frequency termination point, FEP[ml/min] 1005...5000
Frequency at termination point FRP[Hz] 1...10000
communication interface IO-Link
Mode of transmission COM2 (38,4 kBaud)
IO-Link version 1.1
SDCI specification IEC 61131-9
Configurations Intelligent Sensor: Data Process Variable; Device Identification; Device Diagnosis
SIO mode yes
Necessary master port category A
Analog data process 3
Data binary process 2
Minimum process cycle duration[ms] 6
Supported DeviceIDs>
Mode of operationDeviceID
default943

Download Specification for SM4120

Download PDF