Flow Sensor Ifm SD1440


IFM CATEGORIES

Flow Sensor Ifm sd1440

Flow Sensor SD1440

Brand: Ifm
Product Code: SDD11DXXFRKG/US-100

  • Accurate monitoring of flow, consumption, and medium temperature value
  • Excellent precision, reproducibility, and measurement responsiveness
  • For the detection of pressurized air in industrial applications
  • Featuring switching output, analog output, and pulse output
  • Customizable for internal pipe diameters

Share on:

Product characteristics

Total count of inputs and outputs Count of digital outputs: 2; Count of analog outputs: 1
Measuring span
0.6...143.9 m/s0.3...26260 m³/h0.005...437.6 m³/min
Connection for process screw connection G 1 with internal thread
Application for commercial applications
Setup Customizable for internal pipe diameters; ( 14...254 mm)
Media pressurized air; nitrogen (N2)
Intermediate temperature value[°C] -10...60
Minimum force per unit area before bursting
100 bar10 MPa
Pressure classification
50 bar5 MPa
MAWP (for uses in compliance with CRN)[bar] 10
Temperature factor[1/K] ± 0,07 % MW
Precision (within the measurement range) ± (6 % MW + 0,6 % MEW); (reference conditions: diA = 73 mm; inlet pipe length >= 3 m; outlet pipe length >= 0,5 m; reference temperature value: 20...25 °C; norm volume flow: 50...850 Nm³/h)
Reproducibility ± 1,5 % MW
Surrounding temperature value[°C] 0...60
Temperature for storage[°C] -20...85
Max. relative humidity of air[%] 90
Safety feature IP 65; IP 67

Reaction times

Response duration[s] 0.1; (dAP = 0)
Damping process parameter dAP[s] 0...5
Configuration options hysteresis / range; typically open / default closed; current/pulse output; display can be rotated and deactivated; display unit; cumulative counter
Output response output signal; analog output; pulse signal; IO-Link; (customizable)
Electrical engineering design PNP/NPN
Count of digital outputs 2
Output feature typically open / closed; (customizable)
Max. voltage drop at switching output DC[V] 2.5
Continuous current rating of the switching output DC[mA] 150; (per output)
Total analog outputs 1
Analog current output[mA] 4...20; (expandable)
Max. capacity[O] 500
Pulse output signal consumption measurement device
Overcurrent protection yes
Method of overcurrent protection yes (momentary)
Overcurrent protection yes

Inputs / outputs

Total count of inputs and outputs Count of digital outputs: 2; Count of analog outputs: 1
Voltage for operation[V] 18...30 DC; (to SELV/PELV)
Current draw[mA] < 80
Safety feature rating III
Reverse polarity safeguard yes
Activation delay time[s] 1
Inputs reset function
Measuring span
0.6...143.9 m/s0.3...26260 m³/h0.005...437.6 m³/min
Show range
0...172.7 m/s0...31520 m³/h0...525.2 m³/min
Definition of detail level
0.1 m/s0.05 m³/h0.01 m³/min
Setpoint SP
1.4...143.9 m/s0.8...26260 m³/h0.013...437.6 m³/min
Reset threshold rP
0.7...143.2 m/s0.4...26140 m³/h0.007...435.6 m³/min
Analog initiation point ASP
0...115.1 m/s0...21000 m³/h0...350 m³/min
Analog endpoint AEP
28.8...143.9 m/s422...26260 m³/h7.04...437.6 m³/min
Minimal flow termination LFC
0.2...1.4 m/s0.1...260 m³/h0.002...4.4 m³/min
In increments of
0.1 m/s0.01 m³/h0.001 m³/min
communication interface IO-Link
Mode of transmission COM2 (38,4 kBaud)
IO-Link version 1.1
SDCI specification IEC 61131-9 CDV
Configurations Digital Measurement Sensor (0x800A), Identification and Diagnostics (0x4000)
SIO mode yes
Necessary master port category A
Analog data process 8
Data binary process 2
Minimum process cycle duration[ms] 6.8
Supported DeviceIDs>
Mode of operationDeviceID
default1592

Download Specification for SD1440

Download PDF