Flow Sensor Ifm SD5800


IFM CATEGORIES

Flow Sensor Ifm sd5800

Flow Sensor SD5800

Brand: Ifm
Product Code: SDR14DGXFRKG/US-100

  • Accurate measurement of flow, consumption, force per unit area, and medium temperature value
  • Excellent precision, reproducibility, and measurement responsiveness
  • For detecting helium
  • Red/green indicator for easy recognition of the acceptable range
  • The display can be adjusted for optimal alignment

Share on:

Product characteristics

Total count of inputs and outputs Count of digital outputs: 2; Count of analog outputs: 1
Measuring span
0.8...83.4 l/min0.3...27.6 m/s0.05...5 m³/h
Connection for process screw connection G 1/4 with internal thread DN8
Application for commercial applications
Media helium
Intermediate temperature value[°C] -10...60
Minimum force per unit area before bursting[bar] 64
Pressure classification
16 bar1.6 MPa
MAWP (for uses in compliance with CRN)[bar] 9.5
Temperature factor[1/K] ± 0,07 % MW
Precision (within the measurement range) ± (6 % MW + 0.6 % MEW); at an average temperature value of 23 °C
Reproducibility 0,8 % MW + 0,2 % MEW
Surrounding temperature value[°C] 0...60
Temperature for storage[°C] -20...85
Max. relative humidity of air[%] 90
Safety feature IP 65; IP 67

Reaction times

Response duration[s] 0.1; (dAP = 0)
Damping process parameter dAP[s] 0...5
Configuration options hysteresis / range; typically open / default closed; current/pulse output; display can be rotated and deactivated; display unit; cumulative counter
Output response output signal; analog output; pulse signal; IO-Link; (customizable)
Electrical engineering design PNP/NPN
Count of digital outputs 2
Output feature typically open / closed; (customizable)
Max. voltage drop at switching output DC[V] 2.5
Continuous current rating of the switching output DC[mA] 150; (per output)
Total analog outputs 1
Analog current output[mA] 4...20; (expandable)
Max. capacity[O] 500
Pulse output signal consumption measurement device
Overcurrent protection yes
Method of overcurrent protection yes (momentary)
Overcurrent protection yes

Inputs / outputs

Total count of inputs and outputs Count of digital outputs: 2; Count of analog outputs: 1
Voltage for operation[V] 18...30 DC; (to SELV/PELV)
Current draw[mA] < 80
Safety feature rating III
Reverse polarity safeguard yes
Activation delay time[s] 1
Inputs reset function
Measuring span
0.8...83.4 l/min0.3...27.6 m/s0.05...5 m³/h
Show range
0...100 l/min0...33.1 m/s0...6 m³/h
Definition of detail level
0.2 l/min0.1 m/s0.01 m³/h
Setpoint SP
1.3...83.3 l/min0.4...27.6 m/s0.08...5 m³/h
Reset threshold rP
0.9...82.9 l/min0.3...27.5 m/s0.05...4.97 m³/h
Analog initiation point ASP
0...66.6 l/min0...22.1 m/s0...4 m³/h
Analog endpoint AEP
16.7...83.3 l/min5.5...27.6 m/s1...5 m³/h
Minimal flow termination LFC
0.6...0.8 l/min0.2...0.3 m/s0.04...0.05 m³/h
In increments of
0.1 l/min0.1 m/s0.01 m³/h
communication interface IO-Link
Mode of transmission COM2 (38,4 kBaud)
IO-Link version 1.1
SDCI specification IEC 61131-9 CDV
Configurations Digital Measurement Sensor (0x800A), Identification and Diagnostics (0x4000)
SIO mode yes
Necessary master port category A
Analog data process 8
Data binary process 2
Minimum process cycle duration[ms] 7.2
Supported DeviceIDs>
Mode of operationDeviceID
default1301

Download Specification for SD5800

Download PDF