Flow Sensor Ifm SD6101
IFM CATEGORIES
Flow Sensor SD6101
Brand: Ifm
Product Code: SDN12DGXFPKG/US-100
- Accurate monitoring of flow, consumption, and medium temperature value
- Excellent precision, reproducibility, and measurement responsiveness
- Designed for the detection of argon (Ar), carbon dioxide (CO2), and nitrogen (N2)
- Featuring switching output, analog output, and pulse output
- Easily readable numerical display
Product characteristics
| Total count of inputs and outputs | Count of digital outputs: 2; Count of analog outputs: 1 | |||
| Connection for process | screw connection 1/2" NPT with outdoor threading DN15 | |||
| Application | for commercial applications | |||
| Media | Argon (Ar); carbon dioxide (CO2); nitrogen (N2) | |||
| Intermediate temperature value[°F] | 32...140 | |||
| Pressure classification |
| |||
| MAWP (for uses in compliance with CRN)[bar] | 16 | |||
| Response duration[s] | 0.1; (dAP = 0) | |||
| Damping process parameter dAP in increments[s] | 0 - 0,2 - 0,4 - 0,6 - 0,8 - 1 |
Software / programming
| Configuration options | Flow supervision; volume measuring device; preset counter; hysteresis / window; typically open / closed; current/pulse output; display can be adjusted and turned off; display unit; medium selection | ||||
| communication interface | IO-Link | ||||
| Mode of transmission | COM2 (38,4 kBaud) | ||||
| IO-Link version | 1.1 | ||||
| SDCI specification | IEC 61131-9 | ||||
| Configurations | Intelligent Sensor: Data Process Variable; Device Identification; Device Diagnosis | ||||
| SIO mode | yes | ||||
| Necessary master port category | A | ||||
| Analog data process | 3 | ||||
| Data binary process | 2 | ||||
| Minimum process cycle duration[ms] | 4.1 | ||||
| Supported DeviceIDs |
| ||||
| Minimal flow termination LFC |
| ||||
| Measurement dynamics | 1:300 |
Inputs / outputs
| Total count of inputs and outputs | Count of digital outputs: 2; Count of analog outputs: 1 |
| Voltage for operation[V] | 18...30 DC; (to SELV/PELV) |
| Current draw[mA] | < 100 |
| Safety feature rating | III |
| Reverse polarity safeguard | yes |
| Activation delay time[s] | 1 |
| Overall count of outputs | 2 |
| Output response | output signal; analog output; pulse signal; IO-Link; (customizable) |
| Electrical engineering design | PNP |
| Count of digital outputs | 2 |
| Output feature | typically open / closed; (customizable) |
| Max. voltage drop at switching output DC[V] | 2 |
| Continuous current rating of the switching output DC[mA] | 250; (per output) |
| Total analog outputs | 1 |
| Analog current output[mA] | 4...20; (expandable) |
| Max. capacity[O] | 500 |
| Pulse output signal | consumption measurement device |
| Overcurrent protection | yes |
| Method of overcurrent protection | yes (momentary) |
| Overcurrent protection | yes |
| Reproducibility[% of the assessed value] | ± 1,5 |
| Precision (within the measurement range) | ± (6 % MW + 0,6 % MEW); (conditions: installation to DIN ISO 2533; installation in pipes: DN15) |
| Surrounding temperature value[°F] | 32...140 |
| Temperature for storage[°F] | -4...185 |
| Max. relative humidity of air[%] | 90 |
| Safety feature | IP 65 |
Download Specification for SD6101