Flow Sensor Ifm SD6600
IFM CATEGORIES
Flow Sensor SD6600
Brand: Ifm
Product Code: SDR12DGXFRKG/US-100
- Accurate measurement of flow, consumption, force per unit area, and medium temperature value
- Excellent precision, reproducibility, and measurement responsiveness
- For the detection of argon (Ar), carbon dioxide (CO2), nitrogen (N2), and pressurized air
- Red/green indicator for easy recognition of the acceptable range
- The display can be adjusted for optimal alignment
Product characteristics
| Total count of inputs and outputs | Count of digital outputs: 2; Count of analog outputs: 1 | |||
| Measuring span |
| |||
| Connection for process | screw connection R 1/2 outdoor thread DN15 | |||
| Application | for commercial applications | |||
| Media | Argon (Ar); carbon dioxide (CO2); nitrogen (N2); pressurized air | |||
| Intermediate temperature value[°C] | -10...60 | |||
| Minimum force per unit area before bursting |
| |||
| Pressure classification |
| |||
| MAWP (for uses in compliance with CRN)[bar] | 9.7 | |||
| Temperature factor[1/K] | ± 0,07 % MW | |||
| Precision (within the measurement range) | ± (6 % MW + 0.6 % MEW); at an average temperature value of 23 °C | |||
| Reproducibility | ± (0,4 % MW + 0,1 % MEW) | |||
| Surrounding temperature value[°C] | 0...60 | |||
| Temperature for storage[°C] | -20...85 | |||
| Max. relative humidity of air[%] | 90 | |||
| Safety feature | IP 65; IP 67 |
Reaction times
| Response duration[s] | 0.1; (dAP = 0) |
| Damping process parameter dAP[s] | 0...5 |
| Configuration options | hysteresis / range; typically open / default closed; current/pulse output; display can be rotated and deactivated; display unit; cumulative counter |
| Output response | output signal; analog output; pulse signal; IO-Link; (customizable) |
| Electrical engineering design | PNP/NPN |
| Count of digital outputs | 2 |
| Output feature | typically open / closed; (customizable) |
| Max. voltage drop at switching output DC[V] | 2.5 |
| Continuous current rating of the switching output DC[mA] | 150; (per output) |
| Total analog outputs | 1 |
| Analog current output[mA] | 4...20; (expandable) |
| Max. capacity[O] | 500 |
| Pulse output signal | consumption measurement device |
| Overcurrent protection | yes |
| Method of overcurrent protection | yes (momentary) |
| Overcurrent protection | yes |
Inputs / outputs
| Total count of inputs and outputs | Count of digital outputs: 2; Count of analog outputs: 1 | ||||
| Voltage for operation[V] | 18...30 DC; (to SELV/PELV) | ||||
| Current draw[mA] | < 80 | ||||
| Safety feature rating | III | ||||
| Reverse polarity safeguard | yes | ||||
| Activation delay time[s] | 1 | ||||
| Inputs | reset function | ||||
| Measuring span |
| ||||
| Show range |
| ||||
| Definition of detail level |
| ||||
| Setpoint SP |
| ||||
| Reset threshold rP |
| ||||
| Analog initiation point ASP |
| ||||
| Analog endpoint AEP |
| ||||
| Minimal flow termination LFC |
| ||||
| In increments of |
| ||||
| communication interface | IO-Link | ||||
| Mode of transmission | COM2 (38,4 kBaud) | ||||
| IO-Link version | 1.1 | ||||
| SDCI specification | IEC 61131-9 CDV | ||||
| Configurations | Digital Measurement Sensor (0x800A), Identification and Diagnostics (0x4000) | ||||
| SIO mode | yes | ||||
| Necessary master port category | A | ||||
| Analog data process | 8 | ||||
| Data binary process | 2 | ||||
| Minimum process cycle duration[ms] | 7.2 | ||||
| Supported DeviceIDs |
|