Flow Sensor Ifm SD8501


IFM CATEGORIES

Flow Sensor Ifm sd8501

Flow Sensor SD8501

Brand: Ifm
Product Code: SDN11DGXFRKG/US-100

  • Accurate measurement of flow, consumption, force per unit area, and medium temperature value
  • Excellent precision, reproducibility, and measurement responsiveness
  • For the detection of pressurized air in industrial applications
  • Red/green indicator for easy recognition of the acceptable range
  • The display can be adjusted for optimal alignment

Share on:

Product characteristics

Total count of inputs and outputs Count of digital outputs: 2; Count of analog outputs: 1
Measuring span
25...7945 scfh0.4...132.4 scfm1.2...340.2 ft/s
Connection for process screw connection 1" NPT with outdoor threading DN25
Application for commercial applications
Media pressurized air
Intermediate temperature value[°C] -10...60
Minimum bursting force per unit area[psi] 928
Pressure specification[psi] 232
MAWP (for uses in compliance with CRN)[bar] 10.5
Temperature factor[1/K] ± 0,07 % MW
Precision (within the measurement range) class 141: ± (2 % MW + 0,5 % MEW); class 344: ± (6 % MW + 0,6 % MEW) ; air quality according to ISO 8573-1:2010; at an intermediate temperature value of 73 °F
Reproducibility ± (0,4 % MW + 0,1 % MEW)
Surrounding temperature value[°F] 32...140
Temperature for storage[°C] -4...185
Max. relative humidity of air[%] 90
Safety feature IP 65; IP 67

Reaction times

Response duration[s] 0.1; (dAP = 0)
Damping process parameter dAP[s] 0...5
Configuration options hysteresis / range; typically open / default closed; current/pulse output; display can be rotated and deactivated; display unit; cumulative counter
Output response output signal; analog output; pulse signal; IO-Link; (customizable)
Electrical engineering design PNP/NPN
Count of digital outputs 2
Output feature typically open / closed; (customizable)
Max. voltage drop at switching output DC[V] 2.5
Continuous current rating of the switching output DC[mA] 150; (per output)
Total analog outputs 1
Analog current output[mA] 4...20; (expandable)
Max. capacity[O] 500
Pulse output signal consumption measurement device
Overcurrent protection yes
Method of overcurrent protection yes (momentary)
Overcurrent protection yes

Inputs / outputs

Total count of inputs and outputs Count of digital outputs: 2; Count of analog outputs: 1
Voltage for operation[V] 18...30 DC; (to SELV/PELV)
Current draw[mA] < 80
Safety feature rating III
Reverse polarity safeguard yes
Activation delay time[s] 1
Inputs reset function
Measuring span
25...7945 scfh0.4...132.4 scfm1.2...340.2 ft/s
Show range
0...9535 scfh0...158.9 scfm0...408.2 ft/s
Definition of detail level
5 scfh0.1 scfm0.2 ft/s
Setpoint SP
69...7943 scfh1.1...132.4 scfm3...340.1 ft/s
Reset threshold rP
30...7904 scfh0.5...131.7 scfm1.3...338.4 ft/s
Analog initiation point ASP
0...6357 scfh0...105.9 scfm0...272.2 ft/s
Analog endpoint AEP
1589...7946 scfh26.5...132.4 scfm68...340.2 ft/s
Minimal flow termination LFC
9...85 scfh0.2...1.4 scfm0.4...3.6 ft/s
In increments of
1 scfh0.1 scfm0.1 ft/s
communication interface IO-Link
Mode of transmission COM2 (38,4 kBaud)
IO-Link version 1.1
SDCI specification IEC 61131-9 CDV
Configurations Digital Measurement Sensor (0x800A), Identification and Diagnostics (0x4000)
SIO mode yes
Necessary master port category A
Analog data process 8
Data binary process 2
Minimum process cycle duration[ms] 7.2
Supported DeviceIDs>
Mode of operationDeviceID
default867

Download Specification for SD8501

Download PDF