Flow Sensor Ifm SU9021


IFM CATEGORIES

Flow Sensor Ifm su9021

Flow Sensor SU9021

Brand: Ifm
Product Code: SUR54XXBFRKG/US

  • Precise flow measurement for ultrapure water and regular water
  • A durable, component-free measurement tube constructed from stainless steel provides excellent media resistance and long-lasting ingress protection
  • The extremely precise inline measurement method eradicates any impact from differing wall thicknesses and pipe materials
  • Operating status LED indicates the sensor's condition and provides insights into process quality

Share on:

Product characteristics

Measuring span
1...275 l/min0.06...16.5 m³/h16...4359 gph0.26...72.64 gpm
Connection for process screw connection G 1 1/4 with outdoor thread DN32
System gold-plated terminals
Media ultra-pure water; H2O; aqueous media
Comment on medium
water-based fluids: for mediums with >10% additives, the repeatability is the sole available parameter
Intermediate temperature value
-20...100 °C-4...212 °F
Minimum force per unit area before bursting
150 bar15 MPa
Pressure classification
100 bar10 MPa
Vacuum tolerance[mbar] -1000
Response duration[s] < 0.25; (dAP = 0, T09)
Damping process parameter dAP[s] 0...5

Software / programming

diagnostic functions flow detection direction; signal integrity
communication interface IO-Link
Mode of transmission COM2 (38,4 kBaud)
IO-Link version 1.1.3
SDCI specification IEC 61131-9: 2013-07
Configurations
Operation classOverview
0x4000Identification and Fault Detection
Necessary master port category A
Analog data process 3
Data binary process 2
Minimum process cycle duration[ms] 9.6
IO-Link cyclic process data
Operationbit length
cumulative counter32
Flow supervision32
Temperature surveillance32
status4
Output 11
Output 21
Supported DeviceIDs>
Mode of operationDeviceID
default1638
Measuring span
1...275 l/min0.06...16.5 m³/h16...4359 gph0.26...72.64 gpm
Show range
-330...330 l/min-19.8...19.8 m³/h-5231...5231 gph-87.18...87.18 gpm
Definition of detail level
0.1 l/min0.001 m³/h1 gph0.01 gpm
Setpoint SP
2.5...275 l/min0.151...16.5 m³/h40...4359 gph0.66...72.65 gpm
Reset threshold rP
1.1...273.6 l/min0.065...16.414 m³/h17...4336 gph0.29...72.27 gpm
Analog initiation point ASP
-275...220 l/min-16.5...13.2 m³/h-4359...3487 gph-72.65...58.12 gpm
Analog endpoint AEP
-220...275 l/min-13.2...16.5 m³/h-3487...4359 gph-58.12...72.65 gpm
Minimal flow termination LFC
1...13.8 l/min0.06...0.825 m³/h16...218 gph0.26...3.63 gpm
Frequency termination point, FEP
55.2...275 l/min3.31...16.5 m³/h874...4359 gph14.75...72.65 gpm
Frequency at termination point FRP[Hz] 1...10000

Inputs

Inputs reset function
Voltage for operation[V] 18...32 DC; (to SELV/PELV)
Current draw[mA] < 75
Safety feature rating III
Reverse polarity safeguard yes
Activation delay time[s] 5
Measuring method ultrasonics
Overall count of outputs 2
Output response output signal; pulse output; analog output; IO-Link; frequency output; diagnostic output; cumulative counter output signal
Electrical engineering design PNP/NPN
Output feature typically open / closed; (customizable)
Max. voltage drop at switching output DC[V] 2
Continuous current rating of the switching output DC[mA] 100
DC switching frequency[Hz] 0...10000
Analog current output[mA] 4...20
Max. capacity[O] 500
Pulse output signal flow measurement device
Overcurrent protection yes
Method of overcurrent protection yes (momentary)
Overcurrent protection yes
Precision (within the measurement range) ± (1,0 % MW + 0,5 % MEW)
Reproducibility ± 0,2 % MEW
Surrounding temperature value[°C] -20...60
Temperature for storage[°C] -25...80
Safety feature IP 67

Download Specification for SU9021

Download PDF