Flow Sensor Ifm SI6800
IFM CATEGORIES
Flow Sensor SI6800
Brand: Ifm
Product Code: SIR11ABBFPKG/US-100-IPF
- Sanitary design tailored for the demands of the food and beverage sector
- Appropriate for SIP procedures at temperature values up to 140 °C
- LED bar graph for displaying switch point and flow status
- Wide selection of process adapters available in the accessories
- Wetted components constructed from stainless steel
Product characteristics
| Total count of inputs and outputs | Count of digital outputs: 1 | ||
| Connection for process | screw connection G 1 with outdoor thread Aseptoflex Vario | ||
| System | gold-plated terminals | ||
| Application | hygienic systems | ||
| Intermediate temperature value[°C] | -25...95; (for SIP process: ...140 °C) | ||
| Pressure classification |
| ||
| MAWP (for uses in compliance with CRN)[bar] | 30 | ||
| Response duration[s] | 1...10 | ||
| Weight[g] | 440 | ||
| Housing | cylindrical | ||
| measurements[mm] | Ø 50 / L = 154 | ||
| Substance | stainless steel (1.4404 / 316L); PC; PBT-GF20; EPDM/X; sealing: FKM | ||
| Substances (contacted components) | stainless steel (1.4435 / 316L); surface properties: Ra < 0.4 / Rz 4 | ||
| Connection for process | screw connection G 1 with outdoor thread Aseptoflex Vario | ||
| Diameter of probe[mm] | 7.7 | ||
| Setup length IL[mm] | 55 |
Software / programming
| Modification of the switching threshold | tactile switches |
| Surrounding temperature value[°C] | -25...60 |
| Safety feature | IP 67; IP 69K |
| Length L of probe[mm] | 55 |
Inputs / outputs
| Total count of inputs and outputs | Count of digital outputs: 1 | ||
| Voltage for operation[V] | 19...36 DC | ||
| Current draw[mA] | < 60 | ||
| Safety feature rating | III | ||
| Reverse polarity safeguard | yes | ||
| Activation delay time[s] | 10 | ||
| Overall count of outputs | 1 | ||
| Output response | output signal | ||
| Electrical engineering design | PNP | ||
| Count of digital outputs | 1 | ||
| Output feature | typically open / closed; (customizable) | ||
| Max. voltage drop at switching output DC[V] | 2.5 | ||
| Continuous current rating of the switching output DC[mA] | 250 | ||
| Overcurrent protection | yes | ||
| Method of overcurrent protection | yes (momentary) | ||
| Overcurrent protection | yes | ||
| Reproducibility[cm/s] | 1...5 | ||
| Comment on repeatability |
| ||
| Temperature variation[cm/s x 1/K] | 0.1; (for water 5...100 cm/s; 10...70 °C) | ||
| Max. temperature value change rate of medium[K/min] | 300 | ||
| Precision of switch points/span>[cm/s] | ± 2...± 10; (for water 5...100 cm/s; 25 °C; default configuration) | ||
| Hysteresis[cm/s] | 2...5; (for water 5...100 cm/s; 25 °C; default configuration) |