Flow Sensor Ifm SM7001


IFM CATEGORIES

Flow Sensor Ifm sm7001

Flow Sensor SM7001

Brand: Ifm
Product Code: SMR34GGXFRKG/US-100

  • Accurate monitoring of flow, consumption, and medium temperature value
  • Excellent precision, reproducibility, and measurement responsiveness
  • Featuring switching output, analog output, and pulse output
  • Easily readable numerical display

Share on:

Product characteristics

Total count of inputs and outputs Count of digital outputs: 2; Count of analog outputs: 1
Measuring span
3...792 gph0.06...13.2 gpm
Connection for process screw connection G 3/4 outdoor screw thread DN20 with flat gasket
System gold-plated terminals
Application Cumulative function; designed for industrial use
Setup connection to pipe via an adapter
Media Conductive fluids; water; aqueous media
Comment on medium
conductivity: = 20 µS/cm
viscosity: < 70 mm²/s (40 °C)
Intermediate temperature value[°F] 14...158
Pressure classification
16 bar232 psi1.6 MPa
MAWP (for uses in compliance with CRN)[bar] 11.2
Precision (within the measurement range) ± (0,8 % MW + 0,5 % MEW)
Reproducibility ± 0,2% MEW
Surrounding temperature value[°F] 14...140
Temperature for storage[°F] -13...176
Safety feature IP 67

Reaction times

Response duration[s] 0.15; (dAP = 0, T19)
Programmable delay time dS, dr[s] 0...50
Damping process parameter dAP[s] 0...5
Configuration options Flow supervision; volume measuring device; preset tally; temperature value oversight; hysteresis / window; typically open / closed; switching configuration; current/voltage/pulse output; startup delay; display can be turned off; display unit
Overall count of outputs 2
Output response output signal; analog output; pulse signal; IO-Link; (customizable)
Electrical engineering design PNP/NPN
Count of digital outputs 2
Output feature typically open / closed; (customizable)
Max. voltage drop at switching output DC[V] 2
Continuous current rating of the switching output DC[mA] 200
Total analog outputs 1
Analog current output[mA] 4...20; (expandable)
Max. capacity[O] 500
Analog voltage output[V] 0...10; (adjustable)
Minimum load resistance[O] 2000
Pulse output signal flow measurement device
Overcurrent protection yes
Method of overcurrent protection yes (momentary)
Overcurrent protection yes

Inputs / outputs

Total count of inputs and outputs Count of digital outputs: 2; Count of analog outputs: 1
Voltage for operation[V] 18...30 DC; (to SELV/PELV)
Current draw[mA] 95; (24 V)
Safety feature rating III
Reverse polarity safeguard yes
Activation delay time[s] 5
Measuring method magnetic-induction
Inputs reset function
Measuring span
3...792 gph0.06...13.2 gpm
Show range
-951...951 gph-15.84...15.84 gpm
Definition of detail level
1 gph0.02 gpm
Setpoint SP
7...792 gph0.12...13.2 gpm
Reset threshold rP
3...788 gph0.06...13.14 gpm
Analog initiation point ASP
0...636 gph0...10.6 gpm
Analog endpoint AEP
156...792 gph2.6...13.2 gpm
In increments of
1 gph0.02 gpm
communication interface IO-Link
Mode of transmission COM2 (38,4 kBaud)
IO-Link version 1.1
SDCI specification IEC 61131-9
Configurations Intelligent Sensor: Data Process Variable; Device Identification; Device Diagnosis
SIO mode yes
Necessary master port category A
Analog data process 3
Data binary process 2
Minimum process cycle duration[ms] 5
Supported DeviceIDs>
Mode of operationDeviceID
default573

Download Specification for SM7001

Download PDF

RELATED PRODUCTS