Product characteristics

Measuring span
0.5...75 l/min30...4500 l/h0.104...15.601 m/s0.03...4.5 m³/h
Connection for process screw connection G 3/4 outdoor screw thread DN20
System gold-plated terminals
Media ultra-pure water; H2O; water-soluble substances; glycol mixtures; oils; coolants
Comment on medium
water-based fluids: for mediums with >10% additives, the repeatability is the sole available parameter
lightweight oils with viscosity: 7...40 mm²/s (40 °C)
high-viscosity oils with viscosity: 30…68 mm²/s (40 °C)
Intermediate temperature value[°C] -20...100
Minimum force per unit area before bursting
150 bar15 MPa
Pressure classification
100 bar10 MPa
Vacuum tolerance[mbar] -1000
Response duration[s] < 0.25; (dAP = 0, T09)
Damping process parameter dAP[s] 0...5

Software / programming

diagnostic functions flow detection direction; signal integrity
communication interface IO-Link
Mode of transmission COM2 (38,4 kBaud)
IO-Link version 1.1.3
SDCI specification IEC 61131-9: 2013-07
Configurations
Operation classOverview
0x4000Identification and Fault Detection
Necessary master port category A
Analog data process 3
Data binary process 2
Minimum process cycle duration[ms] 9.6
IO-Link cyclic process data
Operationbit length
cumulative counter32
Flow supervision32
Temperature surveillance32
status4
Output 11
Output 21
Supported DeviceIDs>
Mode of operationDeviceID
default1756
Measuring span
0.5...75 l/min30...4500 l/h0.104...15.601 m/s0.03...4.5 m³/h
Show range
-90...90 l/min-5400...5400 l/h-18.721...18.721 m/s-5.4...5.4 m³/h
Definition of detail level
0.1 l/min2 l/h0.001 m/s0.002 m³/h
Setpoint SP
0.9...75 l/min55...4500 l/h0.192...15.601 m/s0.055...4.5 m³/h
Reset threshold rP
0.5...74.6 l/min32...4477 l/h0.112...15.521 m/s0.032...4.477 m³/h
Analog initiation point ASP
-75...60 l/min-4500...3600 l/h-15.604...12.481 m/s-4.5...3.6 m³/h
Analog endpoint AEP
-60...75 l/min-3600...4500 l/h-12.481...15.601 m/s-3.6...4.5 m³/h
Minimal flow termination LFC
0.5...3.2 l/min30...195 l/h0.104...0.676 m/s0.03...0.195 m³/h
Frequency termination point, FEP
15...75 l/min903...4500 l/h3.13...15.601 m/s0.903...4.5 m³/h
Frequency at termination point FRP[Hz] 1...10000

Inputs

Inputs reset function
Voltage for operation[V] 18...32 DC; (to SELV/PELV)
Current draw[mA] < 75
Safety feature rating III
Reverse polarity safeguard yes
Activation delay time[s] 5
Measuring method ultrasonics
Overall count of outputs 2
Output response output signal; pulse output; analog output; IO-Link; frequency output; diagnostic output; cumulative counter output signal
Electrical engineering design PNP/NPN
Output feature typically open / closed; (customizable)
Max. voltage drop at switching output DC[V] 2
Continuous current rating of the switching output DC[mA] 100
DC switching frequency[Hz] 0...10000
Analog current output[mA] 4...20
Max. capacity[O] 500
Pulse output signal flow measurement device
Overcurrent protection yes
Method of overcurrent protection yes (momentary)
Overcurrent protection yes
Precision (within the measurement range)
glycol mixtures (35%)±(5,0 % MW + 0,5 % MEW)
high-viscosity oils with viscosity 46 mm²/s (40 °C)±(5,0 % MW + 1,0 % MEW)
thin oils with viscosity 10mm²/s (40°C)±(5,0 % MW + 1,0 % MEW)
water± (2,0 % MW + 0,5 % MEW)
Reproducibility ± 0,2 % MEW
Surrounding temperature value[°C] -20...60
Temperature for storage[°C] -25...80
Safety feature IP 67

Download Specification for SU7030