Flow Sensor Ifm SU7200


IFM CATEGORIES

Flow Sensor Ifm su7200

Flow Sensor SU7200

Brand: Ifm
Product Code: SUR34HGBFPKG/W/US-100-IPF

  • Consistent monitoring of flow and medium temperature value
  • Compatible with water, oils, and glycol-based solutions
  • Designed for installation within pipes
  • Featuring two programmable switching outputs
  • Easily readable numerical display

Share on:

Product characteristics

Total count of inputs and outputs Quantity of digital outputs: 2
Measuring span
0...50 l/min0...13.2 gpm
Connection for process screw connection G 3/4 outdoor screw thread with flat gasket
System gold-plated terminals
Application for commercial applications
Setup connection to pipe via an adapter
Media water; glycol mixtures; coolants; oils
Comment on medium
lightweight oils with viscosity: 7...40 mm²/s (40 °C)
high-viscosity oils with viscosity: 30…68 mm²/s (40 °C)
Intermediate temperature value[°C] -10...80
Pressure classification
16 bar1.6 MPa
Response duration[s] 0.25; (dAP = 0)
Programmable delay time dS, dr[s] 0...50
Damping process parameter dAP[s] 0...1
Weight[g] 1535.5
Housing rectangular shape
measurements[mm] 110 x 100 x 80.5
Substance enclosure: anodized AlMgSi0.5; sealing: FKM; PA 6.6; protective film: PA
Substances (contacted components) stainless steel (1.4404 / 316L); FKM; PES; Centellen 200
Connection for process screw connection G 3/4 outdoor screw thread with flat gasket

Software / programming

Configuration options Flow detection; Temperature supervision
Surrounding temperature value[°C] -10...60
Temperature for storage[°C] -25...80
Safety feature IP 67
Measuring span
0...50 l/min0...13.2 gpm
Show range
0...60 l/min0...15.9 gpm
Definition of detail level
0.1 l/min0.02 gpm
Setpoint SP
0.1...50 l/min0.04...13.22 gpm
Reset threshold rP
0...49.9 l/min0...13.18 gpm
Max. maximum flow rate[l/min] 60
In increments of
0.1 l/min0.02 gpm

Inputs / outputs

Total count of inputs and outputs Quantity of digital outputs: 2
Voltage for operation[V] 19...30 DC; (to SELV/PELV)
Current draw[mA] 100
Minimum insulation resistance[MO] 100; (500 V DC)
Safety feature rating III
Reverse polarity safeguard yes
Activation delay time[s] 10
Measuring method ultrasonics
Overall count of outputs 2
Output response output signal
Electrical engineering design PNP
Count of digital outputs 2
Output feature typically open / closed; (customizable)
Max. voltage drop at switching output DC[V] 2
Continuous current rating of the switching output DC[mA] 250; (per output)
Overcurrent protection yes
Method of overcurrent protection yes (momentary)
Overcurrent protection yes
Precision (within the measurement range) water: < ± (3 % MW + 0.2 % MEW); glycol (35 %), oil (viscosity 68 mm²/s at 40 °C): < ± (5 % MW + 0.5 % MEW)
Reproducibility 0,1 l/min (0,025 gpm)

Download Specification for SU7200

Download PDF

RELATED PRODUCTS