Inductive Sensor Ifm IE5456


IFM CATEGORIES

Inductive Sensor Ifm ie5456

Inductive Sensor IE5456

Brand: Ifm
Product Code: IEK3006-FRKG/IO/AS

  • Easily visible indication of operational readiness
  • Extended sensing range reduces physical wear and tear
  • Elevated protection rating to meet the demands of challenging industrial conditions

Share on:

Product characteristics

Electrical engineering design PNP/NPN; (customizable)
Output feature typically open / closed; (customizable)
communication interface IO-Link
Housing Screw-type
measurements[mm] M8 x 1 / L = 50
System gold-plated terminals
Surrounding temperature value[°C] -40...75
Safety feature IP 65; IP 66; IP 67; IP 68; IP 69K; (with ifm socket duly screwed on)
Items provided
lock nuts: 2

Tests / approvals

Weight[g] 15.3
Housing Screw-type
Installation non-recessed mountable
measurements[mm] M8 x 1 / L = 50
Thread specification M8 x 1
Substance stainless steel (1.4404 / 316L); sensing surface: white LCP; LED lens: PEI; locking nuts: stainless steel (1.4404 / 316L)
Fastening torque[Nm] A = 5 mm: < 3 Nm; B: < 5 Nm
Adjustment coefficient steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminum: 0.5 / copper: 0.4
Hysteresis[% of Sr] 3...15
Comment on hysteresis
customizable
Linearity error IO-Link[%] ± 3; (of the ultimate measurement range value)
Reproducibility IO-Link[%] ± 2; (of the ultimate measurement range value)
Temperature variation ± 10 %; (of the ultimate measurement range value)

Outputs

Electrical engineering design PNP/NPN; (customizable)
Output feature typically open / closed; (customizable)
Max. voltage drop at switching output DC[V] 2.5
Continuous current rating of the switching output DC[mA] 100
DC switching frequency[Hz] 600
Overcurrent protection yes
Overcurrent protection yes
Voltage for operation[V] 10...30 DC
Current draw[mA] < 15
Safety feature rating III
Reverse polarity safeguard yes
IO-Link for switch points[mm] 1.13...5.61; (customizable)
Measuring span via IO-Link[mm] 0.6...6
communication interface IO-Link
Mode of transmission COM2 (38,4 kBaud)
IO-Link version 1.1
SDCI specification IEC 61131-9
Configurations Intelligent Sensor: Identification and Fault Detection; Multi-channel, two setpoint switching sensor, Type 0 Generic Profiled Sensor; Learning Channel
SIO mode yes
Necessary master port category A
Minimum process cycle duration[ms] 3.2
IO-Link cyclic process data
Operationbit length
measured value16
device status4
two-state switching data2
IO-Link acyclical functions switching cycles counter; switch-on cycle tally; runtime counter; internal temperature value; application-specific label
Supported DeviceIDs>
Mode of operationDeviceID
default1274
Note
For additional details, please refer to the IODD PDF document in the "Downloads" section
Display
Switching condition4 x LED, yellow indicators

Download Specification for IE5456

Download PDF