Pressure Sensor Ifm PM1103


IFM CATEGORIES

Pressure Sensor Ifm pm1103

Pressure Sensor PM1103

Brand: Ifm
Product Code: PM-025-REZ01-E-ZVG/US

  • Durable stainless steel enclosure designed for applications in the food and drink sector
  • Sanitary, flush-mounted design
  • Durable against high-force per unit area washing using harsh cleaning chemicals
  • Excellent resistance to elevated temperature values and elevated protection rating

Share on:

Product characteristics

Total count of inputs and outputs Total digital outputs: 1; Total analog outputs: 1
Measuring span
-1...25 bar-14.6...362.6 psi-0.1...2.5 MPa
Connection for process Clamp DN25...DN40 (1...1.5") DIN 32676 (ISO 2852)
System gold-plated terminals
Sensing element ceramic capacitive force per unit area sensing element
Temperature surveillance no
Application recessed installation compatible for the food and drink sector
Media viscous substances and fluids with suspended particulates; fluids and gases
Intermediate temperature value[°C] -25...150
Minimum force per unit area before bursting
150 bar2175 psi15 MPa
Pressure classification
100 bar1450 psi10 MPa
Comment on force per unit area classification
consider the force per unit area resistance of the bracket and the sealing mechanism utilized for the clamp connection
Vacuum tolerance[mbar] -1000
Kind of force per unit area relative force per unit area; vacuum
No unused space yes
MAWP (for uses in compliance with CRN)[bar] 60
Damping for the analog output dAA[s] 0...4
Weight[g] 369.57
Housing cylindrical
measurements[mm] Ø 30.2 / L = 111.4
Substance stainless steel (1.4404 / 316L); PBT
Substances (contacted components) ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface features: Ra < 0.4 / Rz 4; PTFE
Minimum force per unit area cycles 100 million
Connection for process Clamp DN25...DN40 (1...1.5") DIN 32676 (ISO 2852)

Interfaces

communication interface IO-Link
Mode of transmission COM2 (38,4 kBaud)
IO-Link version 1.1
SDCI specification IEC 61131-9
Configurations Digital Measurement Sensor (0x000A), Identification and Diagnostic (0x4000)
SIO mode no
Necessary master port category A
Analog data process 3
Minimum process cycle duration[ms] 3.2
IO-Link force per unit area accuracy[bar] 0.005
IO-Link cyclic process data
Operationbit length
force per unit area16
device status4
IO-Link acyclical functions application-specific label; internal temperature value
Supported DeviceIDs>
Mode of operationDeviceID
default660
Surrounding temperature value[°C] -25...80
Temperature for storage[°C] -40...100
Safety feature IP 67; IP 68; IP 69K
Measuring span
-1...25 bar-14.6...362.6 psi-0.1...2.5 MPa
Analog initiation point
-1...20 bar-14.6...290 psi-0.1...2 MPa
Analog endpoint
4...25 bar58...362.6 psi0.4...2.5 MPa
In increments of
0.01 bar0.2 psi0.001 MPa
default configuration
ASP = 0.0 barAEP = 25.0 bar

Inputs / outputs

Total count of inputs and outputs Total digital outputs: 1; Total analog outputs: 1
Voltage for operation[V] 18...30 DC
Minimum insulation resistance[MO] 100; (500 V DC)
Safety feature rating III
Reverse polarity safeguard yes
Built-in watchdog yes
Overall count of outputs 2
Output response analog signal; IO-Link; (customizable)
Count of digital outputs 1; (IO-Link)
Total analog outputs 1
Analog current output[mA] 4...20; (expandable)
Max. capacity[O] 700; (Ub = 24 V; (Ub - 9 V) / 21.5 mA)
Short-circuit resistant yes
Overcurrent protection yes
Reproducibility[% of the span] < ± 0,1; (with temperature value fluctuations < 10 K; Turn down 1:1)
Characteristics variation[% of the span] < ± 0,2; (linearity incl. hysteresis and repeatability, limit value setting to DIN EN IEC 62828-1)
Linearity variation[% of the span] < ± 0,15; (Turn down 1:1)
Hysteresis variation[% of the span] < ± 0,15; (Turn down 1:1)
Extended stability[% of the span] < ± 0,1; (Turn down 1:1; per year)
Overall deviation across temperature value range
Operating temperature value rangeoverall deviation
-25...15 °CCharacteristics variation ± 0.05 % of the span / 10 K
15...80 °CCharacteristics variation
80...150 °CCharacteristics variation ± 0.1 % of the span / 10 K
Comments on the precision / variation for additional information refer to the section Diagrams and graphs