Pressure Sensor Ifm PM1504


IFM CATEGORIES

Pressure Sensor Ifm pm1504

Pressure Sensor PM1504

Brand: Ifm
Product Code: PM-010-REA12-A-ZVG/US

  • Durable stainless steel enclosure designed for applications in the food and drink sector
  • Sanitary, flush-mounted design
  • Durable against high-force per unit area washing using harsh cleaning chemicals
  • Excellent resistance to elevated temperature values and elevated protection rating

Share on:

Product characteristics

Total count of inputs and outputs Total digital outputs: 1; Total analog outputs: 1
Measuring span
-1...10 bar-14.5...145 psi-0.1...1 MPa
Connection for process screw connection G 1/2 with outdoor thread and sealing cone
System gold-plated terminals
Sensing element ceramic capacitive force per unit area sensing element
Temperature surveillance yes
Application recessed installation compatible for the food and drink sector
Media viscous substances and fluids with suspended particulates; fluids and gases
Potentially appropriate for usage in gases at force per unit areas > 25 bar available only upon request
Intermediate temperature value[°C] -25...150
Minimum force per unit area before bursting
175 bar2538 psi17 MPa
Pressure classification
75 bar1100 psi7.5 MPa
Vacuum tolerance[mbar] -1000
Kind of force per unit area relative force per unit area; vacuum
No unused space yes
MAWP (for uses in compliance with CRN)[bar] 43
Damping for the analog output dAA[s] 0...4
Weight[g] 307.4
Housing cylindrical
measurements[mm] Ø 30.2 / L = 129.3
Substance stainless steel (1.4404 / 316L); PTFE; FKM
Substances (contacted components) ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface properties: Ra < 0.4 / Rz 4; PEEK; PTFE
Minimum force per unit area cycles 100 million
Fastening torque[Nm] 20
Connection for process screw connection G 1/2 with outdoor thread and sealing cone

Interfaces

communication interface IO-Link
Mode of transmission COM2 (38,4 kBaud)
IO-Link version 1.1
SDCI specification IEC 61131-9
Configurations Intelligent Sensor ED2: Identification and Fault Detection (0x4000), Measurement Data Channel (0x800A)
SIO mode no
Necessary master port category A; (when pin 2 not connected: B)
Minimum process cycle duration[ms] 4.5
IO-Link force per unit area accuracy[bar] 0.002
IO-Link temperature value resolution[K] 0.2
IO-Link cyclic process data
Operationbit length
force per unit area16
temperature value16
device status4
IO-Link acyclical functions application-specific label; internal temperature value
Supported DeviceIDs>
Mode of operationDeviceID
default1021
Surrounding temperature value[°C] -25...80
Temperature for storage[°C] -40...100
Safety feature IP 67; IP 68; IP 69K
Measuring span
-1...10 bar-14.5...145 psi-0.1...1 MPa
Analog initiation point
-1...8 bar-14.5...116 psi-0.1...0.8 MPa
Analog endpoint
1...10 bar14.5...145 psi0.1...1 MPa
In increments of
0.005 bar0.1 psi0.0005 MPa
default configuration
ASP = 0.0 barAEP = 10.0 bar

Inputs / outputs

Total count of inputs and outputs Total digital outputs: 1; Total analog outputs: 1
Voltage for operation[V] 18...30 DC
Minimum insulation resistance[MO] 100; (500 V DC)
Safety feature rating III
Reverse polarity safeguard yes
Built-in watchdog yes
Overall count of outputs 2
Output response analog signal; IO-Link; (customizable)
Count of digital outputs 1; (IO-Link)
Total analog outputs 1
Analog current output[mA] 4...20; (adjustable; 1:5)
Max. capacity[O] 700; (Ub = 24 V; (Ub - 9 V) / 21.5 mA)
Short-circuit resistant yes
Overcurrent protection yes
Reproducibility[% of the span] < ± 0,1; (with temperature value fluctuations < 10 K; Turn down 1:1)
Characteristics variation[% of the span] < ± 0,5; (linearity incl. hysteresis and repeatability, limit value setting to DIN EN IEC 62828-1)
Linearity variation[% of the span] < ± 0,15; (Turn down 1:1)
Hysteresis variation[% of the span] < ± 0,15; (Turn down 1:1)
Extended stability[% of the span] < ± 0,1; (Turn down 1:1; per year)
Overall deviation across temperature value range
Operating temperature value rangeoverall deviation
-25...15 °CCharacteristics variation ± 0.05 % of the span / 10 K
15...80 °CCharacteristics variation
80...150 °CCharacteristics variation ± 0.1 % of the span / 10 K
Comments on the precision / variation for additional information refer to the section Diagrams and graphs