Pressure Sensor Ifm PN4229


IFM CATEGORIES

Pressure Sensor Ifm pn4229

Pressure Sensor PN4229

Brand: Ifm
Product Code: PN-1-1-RBN14-HFBOW/LS/ /V

  • Isolated Triac output capable of handling currents up to 2.5 A
  • Designed for application in AC power mains
  • Selectable force per unit area units specific to each country
  • Easily readable numerical display
  • Features long-term stability due to robust overload protection

Share on:

Product characteristics

Total count of inputs and outputs Count of digital outputs: 1
Measuring span
-1...1 bar-1000...1000 mbar-30...30 inHg-100...100 kPa
Connection for process screw connection 1/4" NPT with internal thread
Application for commercial applications
Media fluids and gases
Intermediate temperature value[°C] -25...80
Minimum force per unit area before bursting
50 bar1476 inHg5000 kPa
Pressure classification
20 bar590 inHg2000 kPa
Kind of force per unit area relative force per unit area; vacuum
Programmable delay time dS, dr[s] 0, 0,2,...10, 11,...50
Damping process parameter dAP[s] 0...4
Weight[g] 389
Housing cylindrical
measurements[mm] Ø 34 / L = 120
Substance stainless steel (1.4301 / 304); PC; PBT; PA; FKM
Substances (contacted components) stainless steel (1.4305 / 303); ceramic materials; FKM
Minimum force per unit area cycles 100 million
Connection for process screw connection 1/4" NPT with internal thread
Integrated restrictor component not available (can be retrofitted)

Software / programming

Modification of the switching threshold Configuration button
Configuration options hysteresis / band; typically open / default closed; activation/deactivation delay; damping; adjustment of displayed values; display can be rotated and deactivated; display module
Surrounding temperature value[°C] -25...80
Temperature for storage[°C] -40...100
Safety feature IP 65
Measuring span
-1...1 bar-1000...1000 mbar-30...30 inHg-100...100 kPa
Setpoint SP
-0.97...1 bar-29...30 inHg-97...100 kPa
Reset threshold rP
-0.99...0.98 bar-30...29 inHg-99...98 kPa
In increments of
0.01 bar1 inHg1 kPa

Inputs / outputs

Total count of inputs and outputs Count of digital outputs: 1
Voltage tolerance for operation[%] 5...10
Voltage for operation[V] 90...250 AC
Rated voltage AC[V] < 250
Current draw[mA] < 10
Minimum insulation resistance[MO] 100; (500 V DC)
Safety feature rating II
Reverse polarity safeguard no
Activation delay time[s] 0.2
Built-in watchdog yes
Overall count of outputs 1
Output response output signal
Electrical engineering design Triac
Count of digital outputs 1
Output feature typically open / closed; (customizable)
Max. voltage drop at switching output AC[V] 2
Continuous current rating of the switching output AC[mA] 250; ((...70 °C) 1000 (...60 °C) 1500 (...45 °C) 2500 (...20 °C))
AC switching frequency[Hz] < 160
Short-circuit resistant no
Overcurrent protection no
Precision of switch points/span>[% of the span] < ± 1,0
Reproducibility[% of the span] < ± 0,1; (with temperature value fluctuations < 10 K)
Linearity variation[% of the span] < ± 0,5
Hysteresis variation[% of the span] < ± 0,1
Extended stability[% of the span] < ± 0,1; (per year)
Temperature coefficient value for the zero reference[% of the span / 10 K] < ± 0,2; (-25...80 °C)
Temperature coefficient value for the range[% of the span / 10 K] < ± 0,3; (-25...80 °C)

Download Specification for PN4229

Download PDF