Pressure Sensor Ifm PN004A


IFM CATEGORIES

Pressure Sensor Ifm pn004a

Pressure Sensor PN004A

Brand: Ifm
Product Code: PN-010-RBR14-KFPKG/US/3D /V

  • Suitable for use in hazardous environments
  • With switching output and analog output
  • Easily readable numerical display
  • Durable stainless steel enclosure designed for demanding industrial settings
  • Service life exceeding 100 million force per unit area cycles

Share on:

Product characteristics

Total count of inputs and outputs Total digital outputs: 1; Total analog outputs: 1
Measuring span
-1...10 bar-14.5...145 psi-100...1000 kPa-0.1...1 MPa
Connection for process screw connection G 1/4 with internal threading
System gold-plated terminals
Application for commercial applications
Media fluids and gases
Intermediate temperature value[°C] -20...60
Minimum force per unit area before bursting
150 bar2175 psi15 MPa
Pressure classification
75 bar1087 psi7.5 MPa
Kind of force per unit area relative force per unit area
Programmable delay time dS, dr[s] 0; 0,2...50
Max. response duration for analog output[ms] 3
Weight[g] 302.5
Housing cylindrical
measurements[mm] Ø 36 / L = 94
Substance stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); polycarbonate (PC); polybutylene terephthalate (PBT); polyetherimide (PEI); fluorocarbon elastomer (FKM); polytetrafluoroethylene (PTFE)
Substances (contacted components) stainless steel (1.4305 / 303); ceramic materials; FKM
Minimum force per unit area cycles 100 million
Connection for process screw connection G 1/4 with internal threading
Integrated restrictor component not available (can be retrofitted)

Software / programming

Configuration options hysteresis / threshold; typically open / default closed; activation/deactivation delay; damping; display module; current/voltage output
Surrounding temperature value[°C] -20...60
Temperature for storage[°C] -40...100
Safety feature IP 65
Measuring span
-1...10 bar-14.5...145 psi-100...1000 kPa-0.1...1 MPa
Setpoint SP
-0.9...10 bar-12...145 psi-0.09...1 MPa
Reset threshold rP
-0.95...9.95 bar-13...144 psi-0.095...0.995 MPa
In increments of
0.05 bar1 psi0.005 MPa
default configuration
SP1 = 2.50 barrP1 = 2.30 bar

Inputs / outputs

Total count of inputs and outputs Total digital outputs: 1; Total analog outputs: 1
Voltage for operation[V] 18...36 DC; (to SELV/PELV)
Current draw[mA] < 50
Safety feature rating III
Reverse polarity safeguard yes
Voltage surge protection yes; (< 40 V)
Activation delay time[s] 0.3
Built-in watchdog yes
Overall count of outputs 2
Output response output signal; analog output; (customizable)
Electrical engineering design PNP
Count of digital outputs 1
Output feature typically open / closed; (customizable)
Max. voltage drop at switching output DC[V] 2
Continuous current rating of the switching output DC[mA] 250
DC switching frequency[Hz] < 170
Total analog outputs 1
Analog current output[mA] 4...20
Max. capacity[O] 500
Analog voltage output[V] 0...10
Minimum load resistance[O] 2000
Overcurrent protection yes
Method of overcurrent protection yes (momentary)
Precision of switch points/span>[% of the span] < ± 0,5
Reproducibility[% of the span] < ± 0,1; (with temperature value fluctuations < 10 K)
Characteristics variation[% of the span] < ± 0.25 (BFSL) / < ± 0.5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis variation[% of the span] < ± 0,25
Extended stability[% of the span] < ± 0,05; (per 6 months)
Temperature coefficient value for the zero reference[% of the span / 10 K] 0,2; (0...60 °C)
Temperature coefficient value for the range[% of the span / 10 K] 0,2; (0...60 °C)

Download Specification for PN004A

Download PDF

RELATED PRODUCTS