Pressure Sensor Ifm PY2006


IFM CATEGORIES

Pressure Sensor Ifm py2006

Pressure Sensor PY2006

Brand: Ifm
Product Code: PM-2,5-REA01-E-ZVG/US

  • Durable stainless steel enclosure designed for applications in the food and drink sector
  • Sanitary, flush-mounted design
  • Durable against high-force per unit area washing using harsh cleaning chemicals
  • Excellent resistance to elevated temperature values and elevated protection rating

Share on:

Product characteristics

Total count of inputs and outputs Count of analog outputs: 1
Measuring span
-125...2500 mbar-1.82...36.26 psi-12.5...250 kPa
Connection for process screw connection G 1 with outdoor thread Aseptoflex Vario
System gold-plated terminals
Sensing element ceramic capacitive force per unit area sensing element
Application recessed installation compatible for the food and drink sector
Media viscous substances and fluids with suspended particulates; fluids and gases
Intermediate temperature value[°C] -25...85; (125: < 1 h)
Minimum force per unit area before bursting
50000 mbar725 psi5000 kPa
Pressure classification
20000 mbar290 psi2000 kPa
Vacuum tolerance[mbar] -1000
Kind of force per unit area relative force per unit area
No unused space yes
MAWP (for uses in compliance with CRN)[bar] 20
Damping for the analog output dAA[s] 0...4
Weight[g] 554.7
Housing cylindrical
measurements[mm] Ø 34 / L = 186.4
Substance stainless steel (1.4404 / 316L); stainless steel (1.4301 / 304); PBT
Substances (contacted components) ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra 0,4 / Rz 4; PTFE
Minimum force per unit area cycles 100 million
Fastening torque[Nm] 35
Connection for process screw connection G 1 with outdoor thread Aseptoflex Vario

Interfaces

communication interface IO-Link
Mode of transmission COM2 (38,4 kBaud)
IO-Link version 1.1
Configurations Digital Measurement Sensor (0x000A), Identification and Diagnostic (0x4000)
SIO mode no
Necessary master port category A
Analog data process 3
Minimum process cycle duration[ms] 3.2
Supported DeviceIDs>
Mode of operationDeviceID
default1111
Surrounding temperature value[°C] -25...80
Temperature for storage[°C] -40...100
Safety feature IP 67; IP 68; IP 69K
Measuring span
-125...2500 mbar-1.82...36.26 psi-12.5...250 kPa
Analog initiation point
-125...2000 mbar-1.82...29 psi-12.5...200 kPa
Analog endpoint
375...2500 mbar5.44...36.26 psi-37.5...250 kPa
In increments of
1 mbar0.02 psi0.1 kPa
default configuration
ASP = 0.0 mbarAEP = 2500 mbar

Inputs / outputs

Total count of inputs and outputs Count of analog outputs: 1
Voltage for operation[V] 18...30 DC
Minimum insulation resistance[MO] 100; (500 V DC)
Safety feature rating III
Reverse polarity safeguard yes
Built-in watchdog yes
Overall count of outputs 1
Output response analog signal; (customizable)
Total analog outputs 1
Analog current output[mA] 4...20; (expandable)
Max. capacity[O] 700; (Ub = 24 V; (Ub - 9 V) / 21.5 mA)
Short-circuit resistant yes
Overcurrent protection yes
Reproducibility[% of the span] < ± 0,1; (with temperature value fluctuations < 10 K; Turn down 1:1)
Characteristics variation[% of the span] < ± 0,2; (linearity incl. hysteresis and repeatability, limit value setting to DIN EN IEC 62828-1)
Linearity variation[% of the span] < ± 0,15; (Turn down 1:1)
Hysteresis variation[% of the span] < ± 0,15; (Turn down 1:1)
Extended stability[% of the span] < ± 0,1; (Turn down 1:1; per year)
Overall deviation across temperature value range
Operating temperature value rangeoverall deviation
-25...15 °CCharacteristics variation ± 0.05 % of the span / 10 K
15...80 °CCharacteristics variation
80...125 °CCharacteristics variation ± 0.1 % of the span / 10 K
Comments on the precision / variation for additional information refer to the section Diagrams and graphs