Inductive Sensor Pepperl+Fuchs NRB15-30GS50-E2-IO-V1
Pepperl+Fuchs Categories
Inductive Sensor NRB15-30GS50-E2-IO-V1
Brand: Pepperl+Fuchs
Product Code:
Datasheet excerpt: Technical data of NRB15-30GS50-E2-IO-V1
| Overall specifications | ||
|---|---|---|
| transition function | Programmable normally open/closed (NO/NC) | |
| Output configuration | PNP | |
| Specified functioning distance | 15 mm (predefined setting) | |
| Proximity functioning range | 10 mm (software activation possible) | |
| mounting | flush | |
| Output configuration | DC | |
| Guaranteed functioning distance | 0 ... 12.15 mm | |
| diminution factor rAl | 1 | |
| diminution factor rCu | 1 | |
| diminution factor r304 | 1 | |
| diminution factor rSt37 | 1 | |
| Output configuration | 3-wire | |
| Rated specifications | ||
| Operational voltage | 10 ... 30 V DC | |
| commutation frequency | 0 ... 600 Hz (switch point mode) 0 ... 25 Hz (window mode, switching point mode with stability warning) |
|
| Deadband | typ. 3 % | |
| Polarity reversal protection | reverse polarity safeguarded | |
| Overcurrent protection | pulsing | |
| voltage loss | = 0.5 V | |
| Operational current | 0 ... 200 mA | |
| Non-conducting current | 0 ... 0.5 mA typ. 60 µA at 25 °C | |
| No-load input current | = 15 mA | |
| Delay time prior to availability | max. 150 ms | |
| Uniform magnetic field | 200 mT | |
| Oscillating magnetic field | 200 mT | |
| Condition indicator | Yellow multihole LED | |
| Parameters related to functional safety | ||
| MTTFd | 362 a | |
| task duration (TM) | 20 a | |
| Diagnostic Range (DC) | 0 % | |
| Connection point | ||
| Type of interface | IO-Link ( via C/Q = pin 4 ) | |
| IO-Link revision | 1.1 | |
| Device ID | 0x201003 (2101251) | |
| data transfer rate | COM2 (38.4 kBit/s) | |
| Minimum cycle time | 2.3 ms | |
| process data range | procedural information entry (control system aspect): 2 Bit procedural information output (control system side): not applicable |
|
| SIO mode support | yes | |
| Compatible master port classification | A | |
| Adherence to standards and directives | ||
| Compliance with standards | ||
| Standards | EN IEC 60947-5-2 | |
| Certifications and approvals | ||
| Ingress protection rating | II | |
| Nominal insulation voltage | 60 V | |
| Rated surge voltage withstand capability | 800 V | |
| UL certification | cULus Certified, Standard Use Class 2 power supply |
|
| CCC certification | CCC certification / marking not necessary for products rated ≤36 V | |
| Environmental conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Ambient storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical characteristics | ||
| Linkage method | plug connector M12 x 1, 4-contact | |
| Housing material | Stainless steel 1.4305 / AISI 303 | |
| detection surface | PBT | |
| Protection等级 | IP67 | |
| Mass | 153 g | |
| Measurements | ||
| Length | 65 mm | |
| Diameter | 30 mm | |
| Default configurations | ||
| Factory configuration | functioning mode = switching point mode with stability alert switching function = normally open (NO) activation distance = 15 mm |
|
| Overview information | ||
| Contents of shipment | 2 self-locking nuts included in the delivery scope | |
Classifications
| Configuration | Classification code |
|---|---|
| ECLASS 13.0 | 27274001 |
| ECLASS 12.0 | 27274001 |
| ECLASS 11.0 | 27270101 |
| ECLASS 10.0.1 | 27270101 |
| ECLASS 9.0 | 27270101 |
| ECLASS 8.0 | 27270101 |
| ECLASS 5.1 | 27270101 |
| ETIM 9.0 | EC002714 |
| ETIM 8.0 | EC002714 |
| ETIM 7.0 | EC002714 |
| ETIM 6.0 | EC002714 |
| ETIM 5.0 | EC002714 |
| UNSPSC 12.1 | 39121550 |