| Overall specifications | ||
|---|---|---|
| Foreground filtration | 0 ... 15 mm | |
| Detection distance | on black (6 %): 20 ... 60 mm fixed configuration | |
| Minimum detection range | 20 ... 60 mm | |
| Maximum detection range | 16 ... 70 mm | |
| Background elimination | begins at 70 mm | |
| illumination source | IRED | |
| Illumination type | modulated infrared light at 880 nm | |
| polarizing filter | no | |
| Black-white contrast (6 %/90 %) | < 1 % at 60 mm | |
| Size of the illumination spot | maximum 6 mm at a distance of 70 mm | |
| angle of opening | approx. 4 ° | |
| Ambient light threshold | 50000 Lux | |
| Parameters related to functional safety | ||
| MTTFd | 1260 a | |
| task duration (TM) | 20 a | |
| Diagnostic Range (DC) | 0 % | |
| Indicators/operation controls | ||
| Operational status indicator | LED in green, continuously illuminated for power on, pulsing (1 Hz) for short-circuit or low voltage conditions; flashing (1 Hz) for pollution | |
| operation indicator | 2 LEDs yellow ON: object detected within the scanning area OFF: item beyond the detection range |
|
| Electrical parameters | ||
| Operational voltage | 10 ... 30 V DC | |
| Ripple | 10 % | |
| No-load input current | max. 25 mA | |
| Input | ||
| Verification input | emitter shutdown at +UB | |
| Output | ||
| Stability fault indication output | 1 push-pull (4 in 1) output, protected against short circuits, reverse polarity protection included | |
| Output signal | 1 push-pull (4 in 1) output, protected against short circuits, reverse polarity protection included | |
| Switching voltage level | max. 30 V DC | |
| Switching capacity | max. 100 mA | |
| voltage loss | = 2.5 V DC | |
| commutation frequency | 250 Hz | |
| reaction time | 2 ms | |
| Compliance | ||
| Product specification | EN 60947-5-2 | |
| Certifications and approvals | ||
| Ingress protection rating | II, rated voltage = 50 V AC with pollution degree 1-2 according to IEC 60664-1 , functional insulation acc. to DIN EN 50178 | |
| UL certification | cULus Certified 57M3 (Only in conjunction with UL Class 2 power supply; Type 1 enclosure) | |
| CCC certification | CCC certification / marking not necessary for products rated ≤36 V | |
| Environmental conditions | ||
| Ambient temperature | 0 ... 70 °C (32 ... 158 °F) | |
| Ambient storage temperature | -40 ... 75 °C (-40 ... 167 °F) | |
| Mechanical characteristics | ||
| Protection等级 | IP67 | |
| Linkage | 5-pin, M12 x 1 connector | |
| Material | ||
| Housing | Aluminum , Delta-Seal coated | |
| optical surface | glass panel | |
| Connector device | metal | |
| Mass | 50 g | |
| Measurements | ||
| Height | 56.5 mm | |
| Width | 31 mm | |
| Depth | 13.6 mm | |