Sensor Accessory Pepperl+Fuchs LVL-A7-AG1A-E5V1-CG-EMS
Pepperl+Fuchs Categories
Sensor Accessory LVL-A7-AG1A-E5V1-CG-EMS
Brand: Pepperl+Fuchs
Product Code:
Datasheet excerpt: Technical data of LVL-A7-AG1A-E5V1-CG-EMS
| Overall specifications | ||
|---|---|---|
| Measurement technique | The tuning fork is brought to its resonance frequency by means of a piezoelectric drive. If the tuning fork is covered by liquid, this frequency changes. The electronics monitor the resonance frequency and indicate whether the tuning fork is freely vibrating or is covered by liquid. | |
| Design type | compact device | |
| Operation mode | MAX = maximum safety: The device keeps the electronic switch closed as long as the liquid level is below the fork. example application: overspill protection MIN = minimum safety: The device keeps the electronic switch closed as long as the fork is immersed in liquid. example application: dry running protection of pumps The electronic switch opens if the limit is reached, if a fault occurs or in the event of a power fails (quiescent current principle) |
|
| Series | LVL-A* | |
| Supply | ||
| Linkage | This device may be used with any sequential circuit, as long as the circuit can support the electrical circuit values of the switching elements. | |
| nominal voltage | 10 ... 35 V DC | |
| Fusing | external 500 mA slow | |
| Current draw | < 15 mA | |
| Energy usage | 975 mW | |
| Residual voltage ripple | 5 V ss at 0 ... 400 Hz | |
| Input | ||
| Measured variable | density | |
| Measurement range | min. 0.7 g/cm3 | |
| Output | ||
| Output configuration | switching output | |
| Switching capacity | max. 250 mA | |
| Compliance with directives | ||
| Electromagnetic interference compliance | ||
| Directive 2014/30/EU Electromagnetic Compatibility | EN 61326-1:2006 , EN 61326-2-3:2006 | |
| Directive 2004/108/EC | EN 61326-1:2006 , EN 61326-2-3:2006 | |
| Compliance | ||
| Electromagnetic interference compliance | NE 21 | |
| Protection等级 | IEC 60529 | |
| Impact resistance | EN 60068-2-27 | |
| vibration durability | EN 60068-2-64 | |
| Climate class | DIN EN 60068-2-38/IEC 68-2-38 | |
| Measurement precision | ||
| Reference functioning conditions | - ambient temperature: 25 °C (+77 °F) - process pressure: 1 bar (14.5 psi) - fluid: water (density: approx. 1 g/cm3, viscosity: 1 mm2/s) - medium temperature: 25 °C (+77 °F) - density setting: > 0.7 g/cm3 - switching time delay: standard (0,5 s, 1 s) |
|
| Measured value resolution | < 0.5 mm | |
| Measuring frequency | approx. 1100 Hz in air | |
| Switching point | 13 mm ± 1 mm | |
| Non-repeatability | ± 1 mm acc. to DIN 61298-2 | |
| Deadband | max. 3 mm | |
| Influence of ambient temperature | negligible | |
| Influence of medium temperature | -25 µm/°C | |
| Influence of medium pressure | -20 µm/bar | |
| Switching time | - 0.5 s when tuning fork is covered - 1.0 s when tuning fork is uncovered |
|
| Activation delay | max. 3 s | |
| Operating conditions | ||
| mounting requirements | ||
| mounting position | see technical information (TI) | |
| Environmental conditions | ||
| Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Ambient storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Impact resistance | a = 300 m/s2 = 30 g, 3 planes x 2 directions x 3 shocks x 18 ms, as per test Ea | |
| vibration durability | a(RMS) = 50 m/s2, ASD = 1.25 (m/s2)2/Hz, f = 5 to 2000 Hz, t = 3 x 2 h | |
| Process conditions | ||
| Medium temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Process pressure (static pressure) | -1 ... +40 bar (-14.5 ... +580 psi) | |
| State of aggregation | liquid | |
| Density | min. 0.7 g/cm3 | |
| Viscosity | 1 ... 10000 mPa/s, dynamic viscosity | |
| Solid contents | < Ø5 mm | |
| Mechanical characteristics | ||
| Protection等级 | IP65 / IP67 , NEMA 4X | |
| Linkage | M12 connector, 4-pole | |
| Material | process connection and short tube: stainless steel 316L (1.4401/1.4435) tuning fork: stainless steel 316L housing cover and connector: PPSU |
|
| Surface quality | Ra < 3.2 µm | |
| Mass | approx. 140 g | |
| Process connection | thread G1/2 to ISO 228 | |
| Indication and operation | ||
| Display elements | The LED display is on the connection side. - green LED: indication of ready to operate - red LED: fault indication - yellow LED: functioning mode indication |
|
| Function test | function test with test magnet (optional accessory) | |
| Certificates and approvals | ||
| CSA certification | cCSAus Listed, Intended for General Use | |
| Overspill protection | see approval (ZE) | |
| Overview information | ||
| Supplementary documentation | technical information (TI) manual (BA) approval (ZE) |
|
| Additional information | Statement of Compliance, Declaration of Compliance, Attestation of Compliance and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
| Accessories | ||
| Identification | see technical information (TI) | |
Classifications
| Configuration | Classification code |
|---|---|
| ECLASS 13.0 | 27200518 |
| ECLASS 12.0 | 27200518 |
| ECLASS 11.0 | 27200518 |
| ECLASS 10.0.1 | 27200518 |
| ECLASS 9.0 | 27200589 |
| ECLASS 8.0 | 27200589 |
| ECLASS 5.1 | 27200589 |
| ETIM 9.0 | EC001447 |
| ETIM 8.0 | EC001447 |
| ETIM 7.0 | EC001447 |
| ETIM 6.0 | EC001447 |
| ETIM 5.0 | EC001447 |
| UNSPSC 12.1 | 41111950 |
Download Specification for LVL-A7-AG1A-E5V1-CG-EMS