Flow Sensor Ifm SA5020


IFM CATEGORIES

Flow Sensor Ifm sa5020

Flow Sensor SA5020

Brand: Ifm
Product Code: SAD10XDBFRKG/US-100

  • Simultaneous measurement of flow and temperature value
  • Dependable airflow measurement
  • Red/green indicator for easy recognition of the acceptable range
  • Featuring switching output, analog signal, and IO-Link
  • The process connection is adjustable for optimal alignment

Share on:

Product characteristics

Total count of inputs and outputs Count of digital outputs: 2; Count of analog outputs: 1
Connection for process screw connection M18 x 1.5 internal thread
System gold-plated terminals
Setup Recommended for pipe diameters; ( 15...51 mm)
Media air
Intermediate temperature value[°C] -20...90
Pressure classification
100 bar10 MPa
MAWP (for uses in compliance with CRN)[bar] 100
Response duration[s] 7

Software / programming

Configuration options hysteresis / range; typically open / default closed; switching method; current/frequency output; medium choice; damping; teach function; display can be rotated and deactivated; norm measurement unit; measured value color
communication interface IO-Link
Mode of transmission COM2 (38,4 kBaud)
IO-Link version 1.1
SDCI specification IEC 61131-9
Configurations Intelligent Sensor: Data Process Variable; Device Identification; Device Diagnosis
SIO mode yes
Necessary master port category A
Analog data process 2
Data binary process 2
Minimum process cycle duration[ms] 3
Supported DeviceIDs>
Mode of operationDeviceID
Factory configuration / ModE = (REL)1237
ModE = (ABS)1238
Length L of probe[mm] 45
Operational mode relative; absolutely gaseous; (absolute: reference measurement recommended; default configuration: relative)
Exhibit range[m/s] 0...36
Definition of detail level[m/s] 0.2
Setpoint SP[m/s] 2...30
Reset threshold rP[m/s] 0.6...28.6
Analog initiation point ASP[m/s] 0...24
Analog endpoint AEP[m/s] 6...30
Frequency termination point, FEP[m/s] 6.6...30
Frequency at termination point FRP[Hz] 100...1000

Inputs / outputs

Total count of inputs and outputs Count of digital outputs: 2; Count of analog outputs: 1
Voltage for operation[V] 18...30 DC; (to SELV/PELV)
Current draw[mA] < 100
Safety feature rating III
Reverse polarity safeguard yes
Activation delay time[s] 10
Measuring method calorimetric
Overall count of outputs 2
Output response output signal; analog output; frequency output; IO-Link; (customizable)
Electrical engineering design PNP/NPN
Count of digital outputs 2
Output feature typically open / closed; (customizable)
Max. voltage drop at switching output DC[V] 2.5
Continuous current rating of the switching output DC[mA] 250
Total analog outputs 1
Analog current output[mA] 4...20; (expandable)
Max. capacity[O] 350
Overcurrent protection yes
Method of overcurrent protection yes (momentary)
Overcurrent protection yes
Output frequency[Hz] 0...1000
Reproducibility ± (3 % MW + 0,6 % MEW)
Surrounding temperature value[°C] -40...80
Temperature for storage[°C] -40...100
Safety feature IP 65; IP 67

Download Specification for SA5020

Download PDF

RELATED PRODUCTS