Flow Sensor Ifm SB1234


IFM CATEGORIES

Flow Sensor Ifm sb1234

Flow Sensor SB1234

Brand: Ifm
Product Code: SBG34KL0FRKG

  • Rapid changes in flow or temperature value do not influence the measurement
  • Enhanced measurement dynamics minimizes variant types
  • No lengths for inlet and outlet pipes are necessary
  • Tailored specifically for oil to achieve optimal measurement outcomes

Share on:

Product characteristics

Measuring span
1...50 l/min0.06...3 m³/h16...793 gph0.26...13.2 gpm
Connection for process screw connection G 3/4 internal thread
System gold-plated terminals
Media Fluids; oils (viscosity of 10 mm²/s at 40 °C)
Intermediate temperature value[°C] -10...100
Pressure classification
100 bar10 MPa
Comment on force per unit area classification
at typical temperature value >70°C: 80 bar / 8 MPa
Configuration options hysteresis / range; typically open / default closed; switching method; current/frequency output; damping for the switching output / analog output; display can be rotated and deactivated; norm measurement unit; measured value color; calibration factor
Weight[g] 989
Substance stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC; brass with chemical nickel plating
Substances (contacted components) stainless steel (1.4401 / 316); stainless steel (1.4404 / 316L); brass (2.0371); brass with chemical nickel plating; PPS; O-ring: FKM
Connection for process screw connection G 3/4 internal thread
Mechanical switching cycles 10 million

Interfaces

communication interface IO-Link
Mode of transmission COM2 (38,4 kBaud)
IO-Link version 1.1
SDCI specification IEC 61131-9 CDV
Configurations Intelligent Sensor: Data Process Variable; Device Identification; Device Diagnosis
SIO mode yes
Necessary master port category A
Analog data process 2
Data binary process 2
Minimum process cycle duration[ms] 3.2
Supported DeviceIDs>
Mode of operationDeviceID
default1045
Surrounding temperature value[°C] 0...60
Comment on operating temperature value range
medium temperature value < 80 °C
medium temperature value < 100 °C: 0...40 °C
Temperature for storage[°C] -15...80
Safety feature IP 65; IP 67
Precision (within the measurement range) ± 5 % MEW; (Q > 1 l/min; 20...70 °C Intermediate temperature value)
Reproducibility ± 1 % MEW

Outputs

Overall count of outputs 2
Output response output signal; analog output; frequency output; IO-Link
Output feature typically open / closed; (customizable)
Max. voltage drop at switching output DC[V] 2
Max. output current capacity[mA] 150; (200: ...60 °C; Surrounding temperature value; 250: ...40 °C; Surrounding temperature value)
Analog current output[mA] 4...20
Max. capacity[O] 500
Overcurrent protection yes
Overcurrent protection yes
Output frequency[Hz] 0...10000
Voltage for operation[V] 18...30 DC; (to SELV/PELV)
Current draw[mA] < 50
Safety feature rating III
Reverse polarity safeguard yes
Activation delay time[s] < 3
Measuring span
1...50 l/min0.06...3 m³/h16...793 gph0.26...13.2 gpm
Show range
0...60 l/min0...3.6 m³/h0...951 gph0...15.86 gpm
Definition of detail level
0.01 l/min0.001 m³/h1 gph0.01 gpm
Setpoint SP
0.35...50 l/min0.02...3 m³/h5...793 gph0.08...13.2 gpm
Reset threshold rP
0...49.65 l/min0...2.98 m³/h0...787 gph0...13.12 gpm
Frequency termination point, FEP
3.35...50 l/min0.2...3 m³/h53...793 gph0.88...13.2 gpm
In increments of
0.05 l/min0.005 m³/h1 gph0.02 gpm
Frequency at termination point FRP[Hz] 10...10000
In increments of[Hz] 10
Measurement dynamics 1:50
Response duration[s] 0.01
Damping process parameter dAP[s] 0...5
In increments of[s] 0.1
Damping for the analog output dAA[s] 0...5
In increments of[s] 0.1

Download Specification for SB1234