Flow Sensor Ifm SD2001


IFM CATEGORIES

Flow Sensor Ifm sd2001

Flow Sensor SD2001

Brand: Ifm
Product Code: SDN21DGXFPKG/US-100

  • Accurate monitoring of flow, consumption, and medium temperature value
  • Excellent precision, reproducibility, and measurement responsiveness
  • For the detection of pressurized air in industrial applications
  • Featuring switching output, analog output, and pulse output
  • Easily readable numerical display

Share on:

Product characteristics

Total count of inputs and outputs Count of digital outputs: 2; Count of analog outputs: 1
Measuring span
90...24720 scfh1.4...412 scfm
Connection for process screw connection 2" NPT with outdoor thread DN50
Application for commercial applications
Media pressurized air
Comment on medium
air quality according to ISO 8573-1
class 141
class 344
Intermediate temperature value[°F] 32...140
Pressure classification
16 bar232 psi1.6 MPa
MAWP (for uses in compliance with CRN)[bar] 16
Response duration[s] 0.1; (dAP = 0)
Damping process parameter dAP in increments[s] 0 - 0,2 - 0,4 - 0,6 - 0,8 - 1
Weight[g] 4269.5
Housing rectangular shape
Substance PBT-GF20; NBR; PC; stainless steel (1.4301 / 304); PTFE; brass-plated; FKM; aluminum powder-coated
Substances (contacted components) stainless steel (1.4301 / 304); fluorocarbon elastomer (FKM); glass-ceramic passivated; polyether ether ketone (PEEK GF30); polyester; aluminum
Connection for process screw connection 2" NPT with outdoor thread DN50

Software / programming

Configuration options Flow supervision; volume measuring device; preset counter; hysteresis / window; typically open / closed; current/pulse output; display can be adjusted and deactivated; display unit
Surrounding temperature value[°F] 32...140
Temperature for storage[°F] -4...185
Max. relative humidity of air[%] 90
Safety feature IP 65
Measuring span
90...24720 scfh1.4...412 scfm
Show range
0...29670 scfh0...494.4 scfm
Setpoint SP
220...24720 scfh3.7...412 scfm
Reset threshold rP
100...24600 scfh1.6...409.9 scfm
Analog initiation point ASP
0...18540 scfh0...309 scfm
Analog endpoint AEP
6180...24720 scfh103...412 scfm
In increments of
10 scfh0.1 scfm

Inputs / outputs

Total count of inputs and outputs Count of digital outputs: 2; Count of analog outputs: 1
Voltage for operation[V] 19...30 DC; (to SELV/PELV)
Current draw[mA] < 100
Safety feature rating III
Reverse polarity safeguard yes
Activation delay time[s] 0.5
Overall count of outputs 2
Output response output signal; analog output; pulse signal; (customizable)
Electrical engineering design PNP
Count of digital outputs 2
Output feature typically open / closed; (customizable)
Max. voltage drop at switching output DC[V] 2
Continuous current rating of the switching output DC[mA] 250; (per output)
Total analog outputs 1
Analog current output[mA] 4...20; (expandable)
Max. capacity[O] 500
Pulse output signal consumption measurement device
Overcurrent protection yes
Method of overcurrent protection yes (momentary)
Overcurrent protection yes
Reproducibility[% of the assessed value] ± 1,5
Precision (within the measurement range) ± (3 % MW + 0,3 % MEW) / ± (6 % MW + 0,6 % MEW); (class 141 /; class 344; conditions: installation to DIN ISO 2533; installation in pipes: DN50)

Download Specification for SD2001

Download PDF