Flow Sensor Ifm SM8420


IFM CATEGORIES

Flow Sensor Ifm sm8420

Flow Sensor SM8420

Brand: Ifm
Product Code: SMK11XGXFRKG/US-100

  • Accurate monitoring of flow, consumption, and medium temperature value
  • Excellent precision, reproducibility, and measurement responsiveness
  • Featuring switching output, analog output, and pulse output
  • Easily readable color display featuring a red/green color transition
  • No lengths for inlet and outlet pipes are necessary

Share on:

Product characteristics

Total count of inputs and outputs Count of digital outputs: 2; Count of analog outputs: 1
Measuring span
0.2...150 l/min0.012...9 m³/h3.6...2378 gph0.06...39.6 gpm
Connection for process screw connection Rc 1 internal thread DN25
System gold-plated terminals
Media Conductive fluids; water; aqueous media
Comment on medium
conductivity: = 20 µS/cm
viscosity: < 70 mm²/s (40 °C)
Intermediate temperature value[°C] -20...90
Pressure classification
16 bar1.6 MPa
Precision (within the measurement range) ± (0,8 % MW + 0,2 % MEW)
Reproducibility ± 0,2 % MEW
Surrounding temperature value[°C] -20...60
Temperature for storage[°C] -25...80
Safety feature IP 65; IP 67

Reaction times

Initialization delay[s] 0...50
Response duration[s] < 0.25; (dAP = 0, T09)
Damping process parameter dAP[s] 0...5
Configuration options hysteresis / band; typically open / default closed; switching method; frequency output; current/pulse output; startup delay; display can be turned off; display module
Overall count of outputs 2
Output response output signal; analog output; pulse signal; IO-Link; frequency signal; (customizable)
Electrical engineering design PNP/NPN
Count of digital outputs 2
Output feature typically open / closed; (customizable)
Max. voltage drop at switching output DC[V] 2
Continuous current rating of the switching output DC[mA] 100
Total analog outputs 1
Analog current output[mA] 4...20; (expandable)
Max. capacity[O] 500
Pulse output signal flow measurement device
Overcurrent protection yes
Method of overcurrent protection yes (momentary)
Overcurrent protection yes

Inputs / outputs

Total count of inputs and outputs Count of digital outputs: 2; Count of analog outputs: 1
Voltage for operation[V] 18...30 DC; (to SELV/PELV)
Current draw[mA] < 80
Safety feature rating III
Reverse polarity safeguard yes
Activation delay time[s] 5
Measuring method magnetic-induction
Inputs reset function
Measuring span
0.2...150 l/min0.012...9 m³/h3.6...2378 gph0.06...39.6 gpm
Show range
-180...180 l/min-10.8...10.8 m³/h-2853.6...2853.6 gph-47.56...47.56 gpm
Definition of detail level
0.1 l/min0.006 m³/h0.6 gph0.01 gpm
Setpoint SP
1...150 l/min0.06...9 m³/h16.2...2376 gph0.27...39.6 gpm
Reset threshold rP
0.2...149.2 l/min0.012...8.95 m³/h3.6...1903 gph0.06...39.42 gpm
Analog initiation point ASP
0...120 l/min0...7.2 m³/h0...1903 gph0...31.71 gpm
Analog endpoint AEP
30...150 l/min1.8...9 m³/h475...2376 gph7.92...39.6 gpm
Minimal flow termination LFC
0.2...7.5 l/min0.012...0.45 m³/h3...118.4 gph0.05...1.98 gpm
Frequency termination point, FEP
30.2...150 l/min1.8...9 m³/h480...2376 gph8...39.6 gpm
Frequency at termination point FRP[Hz] 1...10000
communication interface IO-Link
Mode of transmission COM2 (38,4 kBaud)
IO-Link version 1.1
SDCI specification IEC 61131-9
Configurations Intelligent Sensor: Data Process Variable; Device Identification; Device Diagnosis
SIO mode yes
Necessary master port category A
Analog data process 3
Data binary process 2
Minimum process cycle duration[ms] 6
Supported DeviceIDs>
Mode of operationDeviceID
default966

Download Specification for SM8420